EMM-E6 Ethernet User's Guide

APPENDIX B: COMMONLY-USED OIDs
B
-
10 EMM-E6 User's Guide
B.5 ACTIVATING RMON GROUPS
The initial configuration of the EMM-E6 at installation does not provide
the activation of the RMON Default and Host Groups. These management
groups may be activated or deactivated through local management using
OID Sets. As the specific OID used to control each RMON bundle is
dependent upon the presence or absence of BRIMs and their type, an
SNMP Get is necessary to determine the OID instances of the RMON
bundles before they may be enabled or disabled.
chCompName
Description: Returns OID values for the location of the RMON
bundle OIDs in the device being examined. These values may be
used in conjunction with the chCompAdminStatus OID (below)
to activate and deactivate the individual RMON bundles.
Object Identifier: 1.3.6.1.4.1.52.4.1.1.2.4.1.5
Data Type: Integer
Access Policy: read-write
chCompAdminStatus
Description: Enables and disables the RMON Default Group for
an EMM-E6.
Object Identifier: [Result of above SNMP Get]
Data Type: Integer
Values: 7 disable
3 enable
Access Policy: read-write
CH1Book Page 10 Wednesday, March 20, 1996 7:48 AM