EMM-E6 Ethernet User's Guide

CHAPTER 3: INSTALLATION
3-4 EMM-E6 User’s Guide
Switch definitions are as follows:
Switch 1 - Cabletron Systems use only.
Switch 2 - Cabletron Systems use only.
Switch 3 - For manufacturing use only. Keep in
OFF position.
Switch 4 - MIMREV (Management Interface Module Revision).
This switch remains in the
OFF position for normal operation. Only
if you are using THN-MIM part numbers 9000043-05 and below in
your MMAC-FNB should the switch be in the ON position.
Switch 5 - Baud Rate Default. Allows you to set the Console port’s
baud rate. The OFF position sets the baud rate to 9600. The ON
position sets the baud rate to 2400.
Switch 6 - Forced Download. Changing the state of this switch
(i.e., moving the switch from one position to another) clears
download information from NVRAM and forces the EMM-E6 to
download an image file from the station acting as the EMM-E6’s
BOOTP server.
Changes to switch positions only activate their associated
functions after the EMM-E6 is reset.
NOTE
Do NOT change the state of Switch 6 unless you:
- have a station acting as a BOOTP server, and
that station contains the EMM-E6 image file.
- intend to set up a station to act as a BOOTP
server for the EMM-E6.
NOTE
CH1Book Page 4 Wednesday, March 20, 1996 7:48 AM