User`s guide

9031666 E9 Finding Cases and Using the Library
5-3
Finding Similar Cases
Finding Similar Cases
Follow these steps to find and review cases that are similar to the outstanding
alarm:
1. Do one of the following:
If you are in the Alarm Manager window:
a. Select the alarm that you want to resolve in the SpectroGRAPH
Alarm Manager window. Then invoke SpectroRx from the Icon
Subview menu. The SpectroRx submenu appears.
b. Then, select and click on either the Find Similar Cases or the
Find Similar Cases (Quick) option.
If you are already in SpectroRx with the alarm you want to resolve
selected: In the SpectroRx window, select the Find Similar Cases
option or button.
Another SpectroRx window appears. This window displays a list of cases
similar to the outstanding case.
2. Study the solutions outlined in this list to see if they are appropriate for
your alarm situation. These are listed according to similarity to the
selected case, with the most similar at the top of the list.
The Points beside the case number indicate the degree of similarity
between the similar case and the outstanding case. Cases with the same
number of points are ordered by creation time, with the most recent at the
top.
3. Click on the case that most closely matches your situation (or first select
the case and then click on the Open button). This opens the Alarm Data
Window. See Figure 5-1.
4. Adapt your own solution using the information from the found cases.
If you find appropriate solutions in one of these cases, you can copy the
solutions to the outstanding case with the Copy Solution From option.
(SpectroRx copies the information from both the Solution Detail and
Runable Solution fields to the current case.) Then you can execute the
Runable Solution from SpectroRx with the Run Solution option. The
procedures are described in the next section, Using Runable Solutions.
5. (Optional) Complete and refine the information in the outstanding case.
If you can provide more precise information for the Parameters field,
add or modify parameters in this field.
If possible, refine the command in the Runable Solution field and the
description in the Solution Detail field.
Describe the results of your solution in the Results field.