User`s guide

Commands
cbr_get_case
Integration with 3rd Party Applications SpectroRx (SPECTRUM Resolution Expert)
6-6 User’s Guide 5.0rev1
cbr_get_case
Description: Retrieves a specified case (or a blank case if no case number is
specified).
Syntax: cbr_get_case [case number] [nogui]
Options: nogui Returns information in a string
Returns: If you use the nogui option with the command, SpectroRx returns
the case information in a string format. Otherwise, it returns the
case in a SpectroRx window.
Example: cbr_get_case 5 nogui [Return]
cnum=5|ac=Prob00010009|pcause=CONTACT LOST
SYMPTOMS:
Device has stopped responding to polls.
PROBABLE CAUSES:
1) Device Hardware Failure.
2) Cable between this and upstream device broken.
3) Power Failure.
4) Incorrect Network Address.
5) Device Firmware Failure.
RECOMMENDED ACTIONS:
1) Check power to device.
2) Verify status lights on device.
3) Verify reception of packets.
4) Verify network address in device and SPECTRUM.
5) Cycle power on device and recheck.
6) If above fails, call repair.|kp=model_name=cisco.78
model_type=Rtr_CiscoIGS
model_handle=0x10800dc
ip_address=134.141.142.78
mac_address=0.0.C.5.A8.DD
desc_key_word=IGS-BR;IGS-BPRX;IGS-K;IGS-
landscape=slowaris
alarm_severity=YELLOW
date=Fri 06 Jun 1997 13:15:45 EDT|sol=Runable Solution
outputs the Model Name to the output file in the CBR
directory.|run=/bin/echo $model_name >> $SPECTOP/CBR/
output;
/bin/echo “severity = $alarm_severity” >> $SPECTOP/CBR/
output;|results=Partially resolved|notes=Root permission is
required.|solcat=Solution Summary