User Manual
80-10100000-098–2
8.3 Configuring the KBU 64s Polling Address
So that the COMMAND port of each of the polled KBU 64s can be
individually addressed from the command console, each KBU 64 must
be configured to have a unique polling address.
To do this, from either command line prompt, type:
1> SET POLL xxxxx[CR]
where
xxxxx
represents the unique address, in the range
00001 to 99999.
This poll address should be noted, as the KBU 64 cannot be contacted
without issuing the poll address.
If you are configuring KBU 64s that are already connected to the PSV (or
the Manager Card in the rack), you must enable all the PSV or Manager
card lockout switches except the KBU you wish to access. Once set to
polled the lockout switch can be disabled for that KBU 64.
8.4 Configuring the Polled Command Mode
Having configured the KBU 64 to have a unique polling address, the
command mode of the unit must be altered from its default state
(normal) to reflect the new mode of operation. To do this, from either
command line prompt type:
1> SET CONSOLE xxx[CR]
where
xxx
is POLL, for a unit whose COMMAND port is
connected to a Fivemere Port Sharer PSV4, or
NORMAL, if the unit is controlled by a locally
connected terminal.