User manual
PCB Link Options
80-10100000-09 12–1
12. PCB Link Options
Warning: access to the internal workings of your Kilostream
backup unit is strictly denied to the user.
This section is supplied for reference only, and shows the factory default
link settings.
USER and LINK interface link options are detailed in section 2 of this
manual and are not repeated here.
JP1 ISDN interface definition, centre four pins fitted.
JP15 Relay isolator, fitted at all times.
12.1 COMMAND port links
JP60 Pin 1 to Signal Ground, not fitted
JP61 Pin 1 to Chassis Earth, fitted.
JP64 Loopback 105 from 106, fitted
JP65 Output circuit 106, not fitted
JP66 Generate 109 from 107, fitted
JP67 Generate 109 from 106, not fitted
12.2 ALARM port links
JP62 Pin 1 to Signal Ground, not fitted
JP63 Pin 1 to Chassis Earth, fitted.
JP68 Loopback 105 from 106, fitted
JP69 Output circuit 106, not fitted
JP70 Generate 109 from 107, fitted
JP71 Generate 109 from 106, not fitted