Configuration Commands
80-10100000-09 4–1
4. Configuration Commands
4.1 Introduction
There are two ways you can gain access to, and alter the software
configuration options on your KBU 64;
by direct VT100 terminal access (local connection to the COMMAND
port of your KBU 64)
By Talkwire link (from a remote KBU 64 placing a call to another KBU
64, over the ISDN).
In this section we only refer to local terminal access, remote
configuration is covered in more detail later in this manual.
Terminal connection requires that the KBU 64 COMMAND port is set to
communicate at 9600 bit/s, no parity, 8 data bits, 1 start bit and 2 stop
bits. Although the data rate of the port may subsequently be altered by
software command.
The cable required between your VT100 terminal and KBU 64 should be
a ‘straight through’ V24 cable with D type connectors as described in
section 10.