Configuration Commands
80-10100000-09 4ā15
Please see also section 4.8.4, for the setting of the NETWORK
parameter, when 56K speed is set.
The physical link jumpers must also be set as explained in section 2.
When RA is set to V, both transmit and receive clocks must be present
from the digital leased circuit, for a talkwire restoral to occur. With RA
set to X, only the single clock āSā is used.
4.10 Altering Command Port Speed
The COMMAND port is set to communicate at 9600 bit/s as factory
default. The COMM command is used to alter the COMMAND port
speed to ensure compatibility with your terminal:
1> SET COMM sss[CR]
where:
sss
= Baud rate of 300, 1200, 2400, 4800 or 9600
bit/s.
4.11 Altering Alarm Port Speed
The ALARM command is used to set the ALARM port speed to ensure
compatibility with any connected equipment.
The factory default setting is 2400 bit/s:
1> SET ALARM sss[CR]
where sss is the desired setting (300, 1200, 2400, 4800 or 9600bit/s)
4.12 Configuring Alarm Messages
4.12.1 Defining the Message Format
The LOG command is used to activate or de-activate the ALARM port,
and define how message EVENTs are presented on both COMMAND
and ALARM ports of your KBU 64.
Messages are of two types: either EVENTs or ALERTs;