User manual

KBU 64
User Manual
80-10100000-094–22
To display the current time windows for each channel of your KBU 64
type:
1> WINDOW[CR]
Channel 1 Slot 1 Slot 2 Slot 3 Slot 4
On Off On Off On Off On Off
********** ********** ********** ***********
Monday 00:00 24:00 00:00 00:00 00:00 00:00 00:00 00:00
Tuesday 00:00 24:00 00:00 00:00 00:00 00:00 00:00 00:00
Wednesday 00:00 24:00 00:00 00:00 00:00 00:00 00:00 00:00
Thursday 00:00 24:00 00:00 00:00 00:00 00:00 00:00 00:00
Friday 00:00 24:00 00:00 00:00 00:00 00:00 00:00 00:00
Saturday 00:00 24:00 00:00 00:00 00:00 00:00 00:00 00:00
Sunday 00:00 24:00 00:00 00:00 00:00 00:00 00:00 00:00
This display is specific to each channel. You must change the command line
prompt to ‘2>‘
to display the channel 2 window settings.
1> SET WINDOW xxxy hh:mm HH:MM[CR]
where:
xxx
is the first 3 letters of the day of the week
y
is the window slot number (1 to 4)
hh:mm
is the time in hours and minutes when the
backup is enabled, (on xxxday)
HH:MM
is the time in hours and minutes from which
the backup becomes disabled, (on xxxday)
For example:
1> SET WINDOW MON1 08:00 13:00[CR]
This will restrict the possibility of using backup operation of the channel 1
leased circuit, to between 08:00 to 13:00 on Mondays. This has no
effect on a backup request made on any day other than a Monday. You
can use the same command procedure to action restrictions at other
times on the same day, or other days of the week:
1> SET WINDOW MON2 14:00 19:00[CR]
This will provide the additional possibility of using backup operation of
the channel 1 leased circuit, to between 14:00 to 19:00 on Mondays.
If you set both the ‘hh:mm’ and ‘HH:MM’ to 00:00 then that particular
slot on that day will be turned off and not used. If you set both the