a.
To change the logging flag for a given attribute, select the attribute name from the list. The attribute selected
should be one of the variables in the corresponding IT Service Vision table. For example, select avgBusy1
.
b. To change the attribute’s flag, select
File -> Open Attribute...
SPECTRUM displays the Attribute Edit View window.
c. To enable logging, depress the Logged radio button in the Extended Flags section of the window.
d. To save the change, select:
File -> Save & Close Attr Edit.
SPECTRUM displays a warning similar to the following:
You are not the owner of this attribute.
You will not be able to export this model type and this attribute
later.
Are you sure you want to save these changes?
This message indicates that the changes to the model type will not be saved if SPECTRUM is upgraded. The
changes are only valid for this instance of SPECTRUM and its associated database. Therefore, remember which
model types and attributes that you changed so that you can make these changes again if SPECTRUM updates the
model type definitions.
Repeat for each attribute that you want to use from the IT Service Vision table and is not enabled for logging in
SPECTRUM.
7. Save all changes.
When you are finished, select
File -> Save All Changes
The editor returns you to the Model Type View window.
8. Exit from the editor.
Select
File -> Save to Permanent Catalog -> File -> Exit MTE
9. Restart SpectroSERVER.
To restart the SpectroSERVER, select Start SERVER in the SPECTRUM Control Panel. Check to see that these new
attributes are being logged for a model of this particular model type.