Specifications

SSR 8000/8600 Getting Started Guide 109
Appendix A: Troubleshooting
CoreWatch cannot access the SSR. Use the procedure in “Setting Up SNMP
Community Strings” on page 89 to add an
IP interface to 10/100Base-T port on the
Control Module.
If you have already performed this
procedure, make sure you have properly
installed Cabletron CoreWatch and check
the network connection between the
CoreWatch management station and the
SSR.
The SSR is not resolving DNS names. Use the procedure in “Setting the DNS
Domain Name and Address” on page 92 to
set up DNS.
If you have already performed this
procedure, make sure you can use NS
lookup on the DNS server to get the default
domain.
An SNMP manager cannot access the
SSR.
Use the procedure in “Setting Up SNMP
Community Strings” on page 89 to set up
an SNMP community string and specify a
target for SNMP traps.
If you have already performed this
procedure, enter the snmp show all
command to check the SNMP settings.
Use the traceroute and ping commands to
verify that the SSR can reach the SNMP
management station.
You are unable to ping a certain host. Create and add an IP or IPX interface for the
host. See the SmartSwitch Router User
Reference Manual for information.
If You Experience This Difficulty... Try this Remedy...