Specifications

SSR 8000/8600 Getting Started Guide 63
Chapter 2: Hardware Installation
4. Use a #2 Phillips-head screwdriver to tighten the captive screws on each side of the
DC power supply to secure it to the chassis.
5. Attach wires to the terminal blocks on the front of the unit. To attach a wire, loosen the
terminal screw, insert the exposed end of the wire, and tighten the terminal screw.
6. Connect the safety ground wire to a reliable earth ground.
7. Connect the DC input wiring to a DC power source. See Figure 32 and Figure 33 for a
diagram of the wiring connections between the SSR and a DC power source.
Installing the Control Module
The primary Control Module always resides in the CM slot. If you need to replace the
primary Control Module in the CM slot, or you want to install a redundant Control
Module in slot CM/1, use the following procedure. You will need a #2 Phillips-head
screwdriver to perform this procedure.
The primary Control Module must be installed in slot CM. The redundant Control
Module must be installed in slot CM/1. (See “Chassis” on page 12 for information about
the chassis slots.)
Figure 34 shows an example of how to install a Control Module. The procedure following
the figure describes how to do this.
Figure 34. Installing a Control Module
To install the Control Module:
10/100 Mgmt
Console
SSR-8
SSR-CM-2 CONTROL MODULE
Card Guides
Circuit Card
Metal Plate