Switch User Manual

Configuring the Trap Table
3-8 Trap Messages
Trn Port Usage exceeded T: “n” C: “n” 319
The port statistic % Transmit Port Utilization has exceeded the threshold (T: ÒnÓ)
that was set by the user. (C: ÒnÓ is the current value.)
Severity Informational (Level 4)
Action If this happens frequently, you may need to add ports or reroute
some trafÞc.
Receive Yellow Alarm Condition Set 338
A Yellow Alarm was received.
Severity Major (Level 2)
Action Contact your T1 carrier.
Receive Yellow Alarm Condition Set 339
The condition that caused event 338 has been cleared
Severity Informational (Level 4)
LIC “n” Installed, Not Configured 377
The speciÞed Line Interface Card (LIC) exists in the node, but has not been
conÞgured in the Line Processor Þle.
Severity Minor (Level 3)
Action ConÞgure the LIC or remove it from the node.
LIC “n” Configured, Not Installed 378
The speciÞed Line Interface Card (LIC) has been conÞgured in the Line Processor
Þle, but does not exist in the node.
Severity Critical (Level 1)
Action Install the LIC or delete its record.
LIC “n” Config Mismatch—Type “n” 379
The interface type of the speciÞed Line Interface Card (LIC) installed in the node
is different from the interface type conÞgured in the Line Processor Þle. As a
result, the software does not load properly and will not operate.
Severity Major (Level 2)
Action Change either the card or the Þle.
Link Enabled 400
The port has been enabled from the On-Line Port Operations menu.
Severity Major (Level 2)