Specifications
Table Of Contents
- Title
- Notice
- Contents
- Introduction
- Performance Views
- Interface Device View
- Device Topology View
- Applications Views Summary
- St1kNodeApp
- ST1kAccessApp
- ST1kModuleApp
- ST1kLgmApp
- ST1kFsmApp
- ST1kSgmApp
- ST1kAd10App
- ST1kRtmApp
- ST1kChnlApp
- ST1kINLApp
- ST1kFrmRlyApp
- ST1kBundleApp
- ST1kE1PortApp
- ST1kT1PortApp
- ST1kSdmPortApp
- ST1kAsmApp
- ST1kVoiceApp
- ST1kAsmX50App
- ST1kDsmApp
- ST1kDsmPortApp
- ST1kAlarmApp
- Device Configuration View
- Model Information Views
- Index
ST1kSdmPortApp SDM Port Configuration View
SPECTRUM Enterprise Manager 134 of 194 Ascom TimePlex ST-1000
• s is for subrate speeds.
• b is for bundle speeds (n x 64K).
• sf is for stuffed speeds (n x 56K).
• bsf is for speeds that can be bundled (b8bit)
or stuffed (b7bit) depending on the value of
Bit Mode.
• sf56k is switched 56k if Device Type is
2
.
• The default value is
b64k.
Interface
A read-write field with a possible value of
dte1
(the default value),
dte2
,
dte3
,
dce1
,
dce2
, or
dce3
.
TxClockSource
A read-write field with a possible value of
receive
,
send
, or
system
(the default value).
Bit Mode
A read-write field with a possible value of
b7bit
or
b8bit
(the default value).
OOSOper
A read-write field with a possible value of
doNothing
(the default value),
forceFNS
,
mark
,
markFF
,
space
, or
spaceFF
.
PortGen
A read-write field with a possible value of
dsrDtr
or
trans
(the default value).
Polarity
A read-write field with a possible value of
inverted
or
normal
(the default value).
Port Type
A read-write field with a possible value of
null
(the default value),
io
,
bandContent
,
inl
, or
fsm16Connect
.
INL Number
A read-only field with a value ranging from
0
to
31
, with
0
being the default value. This field is
applicable only if Port Type is set to
inl
.
Device Type
A read-write field that shows the type of device
connected to the port. The default value is
3
. The
possible values are as follows:
• Values
1
through
10
and
255
are reserved by
ST-50, of which
1
is for voice,
2
is for switch
56,
3
is for clear channel, and
255
is for INL.
• Values
11
through
254
can be defined by you
for other device types.
For TDM channels connected between I/O ports,
the channel will not connect if the device types do
not match. For I/O to server port connections, the
device types will not be compared.
This field is not used by the ST-1000 node if Port
Type is
null
or
inl
. If Port Type is
inl
but this
field is not
255
, the INL will not be failed. Also, if