Installation guide
SSR-600 Installation Guide 3-1
CHAPTER 3
INSTALLATION
This chapter outlines the procedure for setting up the SSR-600 and
attaching it to the network. Ensure that the network meets the guidelines
and requirements outlined in Chapter 2 before installing the SSR-600.
Sections of this installation procedure may require the following items:
• Antistatic wrist strap (provided with the SSR-600)
• Phillips screwdriver
3.1 GUIDELINES FOR INSTALLATION
Installation sites must be within reach of the network cabling and meet
the requirements listed below:
• A properly grounded power receptacle must be within seven feet of the
location. If using the SSR-600-D, two power receptacles on two
different circuits are recommended for redundancy. One receptacle is
sufficient for the SSR-600-S.
• In a shelf installation, the shelf must be able to support 13.8 kg
(30.4 lb) of static weight for each device on the shelf.
• Maintain a temperature of between 5°C (41°F) and 40°C (104°F) at
the installation site with fluctuations of less than 10°C (50°F) per hour.
• Maintain a two-inch clearance for each side and the back of the device
for adequate ventilation.
Only qualified personnel should perform installation
procedures.
!
CAUTION
Do not connect SWPIM ports to the network before they are
configured. The WAN connection can be cut off by the phone
company if the SWPIM is not configured properly, or is
connected before being configured.