Installation guide
254 Installation Guide for Clients
Spider Communications SC-100E
Required entry:
• drivername = spider$
The following table summarizes the possible entries and values in the
[spider] section of the LAN Manager PROTOCOL.INI file:
Entry Units Range Default
drivername — — spider$
interrupt integer 2-7 3
iobase hex. 200-3E0 300
sramsize integer 8-32 8
Entries in the [spider] section of the LAN Manager PROTOCOL.INI file
have the following meanings:
drivername
Identifies the device driver name.
interrupt
Indicates the interrupt level of the network adapter.
iobase
Identifies the I/O base address. This value should match the jumper
setting selected on the adapter. Values can range from 200 to 3E0,
hexadecimal, in steps of 20 hexadecimal, such as 280, 2A0, 2C0, and
so on.
sramsize
Selects the amount of static RAM in the adapter, either 8K or 32K.