Specifications
Repeater Configuration View
Trap Configuration
Configuration Views EMME/EMM-E6
3-10 Management Module Guide
Trap Configuration
This area of the Repeater Configuration view allows you to enable or disable
any of the following types of traps:
Link Traps
This menu button, when enabled, allows all packets indicating a change in
link status to be reported within the trap database. Possible menu selections
are: Disable, Enable, and other.
Segmentation Traps
This menu button, when enabled, allows all packets indicating a change in
segmentation status to be reported within the trap database. Possible menu
selections are: Disable, Enable, and other.
Source Address Traps
This menu button, when enabled, allows all packets indicating a change in
source address to be reported within the trap database. Possible menu
selections are: Disable, Enable, and other.
Alarm Configuration
This area of the Repeater Configuration view provides configuration
information on generating alarms for the selected module. This section
contains the following fields:
Timebase
Displays the time interval, in seconds, within which the specified number of
errors needs to occur before the alarm is generated. This time interval is
user-configurable. The lowest allowable value is 10.
Traffic Alarms
This menu button allows you to enable or disable detection of Traffic Alarms.
Possible menu selections are: Enable and Disable.
Traffic Threshold
Displays the threshold value within the alarm timebase which, once that
number of packets is exceeded, generates a traffic alarm. This field is
user-configurable. The allowable range is 1 to ~4 billion.
Collision Alarms
This menu button allows you to enable or disable detection of Collision
Alarms. Possible menu selections are Enable and Disable.
Collision Threshold
Displays the threshold value within the alarm timebase which, once that
number of collisions per good packet is exceeded, generates a collision alarm.
This value is user-configurable. Allowable range is 1 to 15 collisions per good
packet.