Specifications
Station Alarm Thresholds View
Configuration Views TRMM -2/ -4
3-10 Management Module Guide
Station Alarm Thresholds View
You can access this view through the Ring Security button in the
Configuration view or through the Alarms Table button in the 802.5 Station
Isolating Errors view described later in this chapter. This view displays a
Station Alarm Thresholds Table containing information for all stations
directly connected to the TRMM-2/-4 device, buttons to manipulate the
information in the table, and buttons to access other views.
Ring Name
The ASCII name assigned to this ring. This name defaults to Network n,
where n is a unique integer value.
Ring Number
The number of the attached ring. If SPECTRUM cannot determine the
number of the ring, a zero is returned.
Ring Speed
The speed of the ring, which can have a value of 4 or 16 megabits.
Ring Status
The operational state of the ring.
Active Monitor
The MAC address of the active monitor for the ring. This address will appear
in any tables with an asterisk (*) to identify it.
Station Address
The MAC address of the station to which this information pertains.
Station Name
The ASCII name assigned to this station.
Line
The current alarm threshold setting for line errors on the device.
Burst
The current alarm threshold setting for burst errors on the device.
A/C
The current alarm threshold setting for address/copied errors on the device.
Internal
The current alarm threshold setting for internal errors on the device.
Congestions
The current alarm threshold setting for congestion errors on the device.
This button updates the contents of the Station Alarm Thresholds Table.
Update