Checking the Site
Environmental Requirements
Environmental requirements for temperature and humidity must be within the
ranges shown in Table 2-3.
Table 2-3. Environmental Specifications of the Access Server 316
Parameter Minimum Maximum
Temperature
1
1. For high altitude sites, decrease the operating temperature
specification by 1.8
o
C for each 1000 m (1
o
F for each 1000 ft) above sea
level.
Operating 5
o
C (41
o
F) 50
o
C (122
o
F)
Nonoperating - 40
o
C (- 40
o
F) 66
o
C (151
o
F)
Maximum rate of
temperature change per hour
20
o
C (36
o
F)
Altitude
Operating 2438 m (8000 ft)
Nonoperating 4876 m (16000 ft)
Relative
Humidity
Operating (noncondensing) 10% 95%
Nonoperating (noncondensing) 10% 95%