Control Modules
3. Press the Hot Swap button or enter the following from the CLI:
4. When the module is ready to remove, the Offline LED will turn ON and all other LEDs will
turn OFF. Figure 3 shows the location of the LEDs and Hot Swap buttons on Control
Modules.
Figure 3. Location of Offline LED and Hot Swap button on a Control Module
Note: If you have deactivated a Control Module and want to activate it again, simply pull it
from its slot and push it back in again. The module is activated automatically. If you
deactivated the module with the system hotswap out command but did not remove
the module, you can reactivate it with the system hotswap in command:
Removing the Backup Control Module
WARNING The X-Pedition and its components are sensitive to static discharge. To prevent
electrostatic damage, observe the guidelines provided in Preventing Electrostatic
Damage on page 15.
1. Identify the Backup Control Module.
xp# system hotswap out slot <number>
xp# system hotswap in slot 1