Datasheet

Cactus Technologies, Limited
1.2.3. Power Supply Requirements

<
!"!:(;"
2.Product Speci+cations
#.#%
"
2.1. System Environmental Speci+cations
Table 2-1. Environmental Speci+cations
Cactus Technologies
®
Commercial CFast
Temperature Operating: 0° C to +70° C (Standard)
-40° C to 85° C (Extended)
Humidity Operating & Non-
Operating:
8% to 95%, non-condensing
Vibration Operating & Non-
Operating:
20G, MIL-STD-883G Method
2005.2, Condition A
Shock Operating & Non-
Operating:
3,000 G, MIL-STD-883G
Method 2002.4, Condition C
Altitude (relative to sea
level)
Operating & Non-
Operating:
100,000 feet maximum
Note: Extended temperature parts are temperature screened only, long term reliability could be compromised
if the parts are used at extended temperatures for long periods of time.
2.2. System Power Requirements
Table 2-2. Power Requirements
Cactus Technologies
®
Commercial
CFast
DC Input Voltage (VCC)
100 mV max. ripple (p-p)
3.3V ±5%
(Maximum Average
Value)
See Notes.
Idle:
Reading:
Writing:
90 mA
410 mA
530 mA
Cactus Technologies Limited Commercial Grade -240S Series CFast Card Product Manual v1.3 7