5.1.6. Idle-97H, E3H
Table 5-17. Idle
Bit -> 7 6 5 4 3 2 1 0
Command (7)
E3H or 97H
C/D/H (6)
X Drive X
Cyl High (5)
X
Cyl Low (4)
X
Sec Num (3)
X
Sec Cnt (2)
X
Feature (1)
X
These commands are treated as NOPs by the drive. Since the drive goes into sleep mode after every
command, these extra IDLE commands are redundant.
5.1.7. Idle Immediate-95H, E1H
Table 5-18. Idle Immediate
Bit -> 7 6 5 4 3 2 1 0
Command (7)
E1H or 95H
C/D/H (6)
X Drive X
Cyl High (5)
X
Cyl Low (4)
X
Sec Num (3)
X
Sec Cnt (2)
X
Feature (1)
X
5.1.8. Initialize Drive Parameters-91H
Bit -> 7 6 5 4 3 2 1 0
Command (7)
91H
C/D/H (6)
X 0 X Drive Max Head (no. of heads-1)
Cyl High (5)
X
Cyl Low (4)
X
Sec Num (3)
X
Sec Cnt (2)
Number of Sectors
Feature (1)
X
Table 5-19. Initialize Drive Parameters
The Initialize Drive Parameters command in Table 5-19 causes the drive to set BSY, enter the Idle
(Read) mode, clear BSY and generate an interrupt. This command enables the host to set the
number of sectors per track and the number of heads per cylinder. Only the Sector Count and the
Drive/Drive/Head registers are used by this command. This command is obsolete in ATA5 but is
supported for backwards compatibility.