Bit -> 7 6 5 4 3 2 1 0
Command (7)
20H or 21H
C/D/H (6)
1 LBA 1 Drive Head (LBA 27-24)
Cyl High (5)
Cylinder High (LBA 23-16)
Cyl Low (4)
Cylinder Low (LBA 15-8)
Sec Num (3)
Sector Number (LBA 7-0)
Sec Cnt (2)
Sector Count
Feature (1)
X
Table 5-23. Read Sectors
5.1.13. Read Verify Sector(s)-40H, 41H
The Read Verify Sector(s) command in Table 5-24 is identical to the Read Sectors command, except
that DRQ is never set and no data is transferred to the host. When the command is accepted, the
drive sets BSY.
When the requested sectors have been veried, the drive clears BSY and generates an interrupt.
Upon command completion, the Command Block Registers contain the cylinder, head, and sector
number of the last sector veried.
If an error occurs, the verify terminates at the sector where the error occurs. The Command Block
Registers contain the cylinder, head and sector number of the sector where the error occurred. The
Sector Count Register contains the number of sectors not yet veried.
Bit -> 7 6 5 4 3 2 1 0
Command (7)
40H or 41H
C/D/H (6)
1 LBA 1 Drive Head (LBA 27-24)
Cyl High (5)
Cylinder High (LBA 23-16)
Cyl Low (4)
Cylinder Low (LBA 15-8)
Sec Num (3)
Sector Number (LBA 7-0)
Sec Cnt (2)
Sector Count
Feature (1)
X
Table 5-24. Read Verify Sectors