5.4.5. Correctable ECC Error Attribute
This attribute gives information about the total number of correctable ECC errors on ash read
commands. The data structure of this attribute is as follows:
Oset Value Description
0 204 Attribute ID
1 – 2 0002h Flags – Advisory type, attribute is updated during normal operation
3 64h Attribute value – xed at 100
4 64h Attribute value – xed at 100
5 – 8 Total number of correctable ECC errors
9 – 10 --
11 00h Reserved
5.4.6. UDMA CRC Error Attribute
This attribute gives information about the total number of UDMA CRC errors on ash read
commands. The data structure of this attribute is as follows:
Oset Value Description
0 199 Attribute ID
1 – 2 0002h Flags – Advisory type, attribute is updated during normal operation
3 64h Attribute value – xed at 100
4 64h Attribute value – xed at 100
5 – 8 Total number of UDMA CRC errors
9 – 10 --
11 00h Reserved
5.4.7. Total Number of Reads Attribute
This attribute gives information about the total number of ash read commands. The data structure
of this attribute is as follows:
Oset Value Description
0 232 Attribute ID
1 – 2 0002h Flags – Advisory type, attribute is updated during normal operation
3 64h Attribute value – xed at 100
4 64h Attribute value – xed at 100
5 – 10 Total number of ash read commands
11 00h Reserved