Instruction Manual

503 Series Industrial Grade CompactFlash Card Product Manual v2.1Cactus Technologies
®
41
5.4.8. Power On Count Attribute
This attribute gives information about the total number of power on cycles. The data structure of
this attribute is as follows:
Oset Value Description
0 12 Attribute ID
1 – 2 0002h Flags – Advisory type, attribute is updated during normal operation
3 64h Attribute value – xed at 100
4 64h Attribute value – xed at 100
5 – 8 Total number of power on cycles
9 – 10 --
11 00h Reserved
5.4.9. Total LBAs Written Attribute
This attribute gives information about the total amount of data written in units of 32MB. The data
structure of this attribute is as follows:
Oset Value Description
0 241 Attribute ID
1 – 2 0002h Flags – Advisory type, attribute is updated during normal operation
3 64h Attribute value – xed at 100
4 64h Attribute value – xed at 100
5 – 10 Total number of LBAs written, divided by 65536
11 00h Reserved
5.4.10. Total LBAs Read Attribute
This attribute gives information about the total amount of LBAs read in units of 32MB. The data
structure of this attribute is as follows:
Oset Value Description
0 242 Attribute ID
1 – 2 0002h Flags – Advisory type, attribute is updated during normal operation
3 64h Attribute value – xed at 100
4 64h Attribute value – xed at 100
5 – 10 Total number of LBAs read, divided by 65536
11 00h Reserved