Instruction Manual

503 Series Industrial Grade CompactFlash Card Product Manual v2.1Cactus Technologies
®
45
5.5.12. TRIM Status Attribute Threshold
Oset Value Description
0 215 Attribute ID
1 00h None dened
2 - 11 00h Reserved
SMART Return Status
5.6.
For this command to take eect, the following signature bytes must be loaded:
Cylinder Low – 4Fh
Cylinder High – C2h
This commands checks the health of the device. If either the Spare Block Count or the Erase Count
attribute exceeded the factory preset threshold, signature values will be returned in the Cylinder
Low/High registers as follows:
Cylinder Low – F4h
Cylinder High – 2Ch
If the thresholds are not exceeded, the Cylinder Low/High registers retains the initially loaded 4Fh/
C2h values.
SMART Read Log
5.7.
For this command to take eect, the following signature bytes must be loaded:
Cylinder Low – 4Fh
Cylinder High – C2h
This command will return data of the SMART log. The following log addresses are dened:
Address Description
0x00 Log Directory
0x80 – 0x9F Host Vendor Specic Logs
0xA0 Reserved
0xA1 Reserved
0xA2 Reserved
The Log Directory at address 0x00 returns one sector of data that shows the number of sectors for
Log addresses 1 to 255: