Operation Manual
22
Country of Use
BE, CH, CY, CZ, ES, FR, GB, GR, IE,
IT, LT, LU, LV, PT, SK & SI
PL
BE, CY, DK, EE,
FR, FI, HU, IT,
LT, NL, NO, SE,
SI, SK, RO, HR,
TR, BG, IS,LU,
MT, & ZA
AT, CH, DE & SK
Appliance Catagories I
3+(28-30/37)
I
3B/P (37)
I
3B/P (30)
I
3B/P (50)
Allowable gasses Butane-30 Propane-31 Butane-30, Propane-31 or their mixture
Gas Pressure 28-30mBar 37mBar 37mBar
28-30mBar
(2.8kPa for South
Africa)
50mBar
Jet Number 0.71
0.71
0.71 0.62
Nominal Usage
291g/hr 320g/hr 291g/hr 291g/hr
Gross nom. heat input
4.0kW 4.4kW 4.0kW 4.0kW
Country Name and Abbreviations
AE = United Arab Emirates AL = Albania AT = Austria BE = Belgium CH = Switzerland
CZ = Czech Republic DE = Germany DK = Denmark ES = Spain FI = Finland
FR = France GB = United Kingdom GR = Greece HR = Croatia IT = Italy
JP = Japan KR = Korea NL = Netherlands NO = Norway PL = Poland
PT = Portugal RO = Romania RU = Russia RS = Serbia SI = Slovenia
SK = Slovakia SE = Sweden TR = Turkey ZA = South Africa
3. Assembly Instructions
• PLEASE NOTE: Please ensure all protective packaging and plastic are removed from the appliance before use.
• This appliance may only be used with an approved hose and regulator (hose and regulator supplied with this unit in South Africa)
• Connect the regulator to a CADAC 3kg, 5kg or 7kg LPG cylinder prior to use.
• If you wish to use the appliance with a 9kg cylinder, please ensure that you have purchased the correct hose and regulator suitable for
a 9kg cylinder.
• The hose length should be no less than 600 mm and shall not exceed 1.2 m and replace when the hose is damaged or shows signs of
brittleness or cracks.
• Do not twist or pinch the hose. Ensure that it is routed away from the Stove Body so as to prevent deterioration / damage to the hose
caused by heat.
• Ensure that the appliance valves are in the off position by turning the knobs fully clockwise to the stop.
• Open the gas valve on the cylinder and test for any leaks.
• Check all gas connections for any signs of gas leaks.
• Your appliance is now ready to be used.
I 3B/P (30), I 3+ (28-30/37) and I 3B/P (37), Appliance categories: (DK, FI, NO, NL, SE, AT, DE, BE, ES, FR, IE, IT, PT, GB, CH)
Push an approved hose onto the valve tailpiece until it is properly seated. On the other end, attach a suitable low pressure regulator.
I3B/P(30) : 30mbar Butane con gurations regulator or 30mbar Propane con gurations regulator.
I3B/P(37) : 37mbar Butane con gurations regulator or 37mbar Propane con gurations regulator.
I3+(28-30/37) : 30mbar Butane con gurations regulator or 37mbar Propane con gurations regulator.
Again making sure that the hose is properly seated. The type of hose used shall comply with the relevant EN standard and locate
requirement. In South Africa the regulator used must comply with SANS 1237.
I 3B/P (50) Appliance category: (AT, DE)
I3B/P(50) : 50mbar Butane con gurations regulator or 50mbar Propane con gurations regulator or 50mbar butane/propane mixture
con gurations regulator.
Screw a hose with the correct threaded ttings on each end, onto the left hand 1/4” BSP thread of the valve. Attache a suitable 50mbar
low-pressure regulator on the end of the hose. The hose assembly used must comply with DIN 4815 part 2 or equivalent.