Operation Manual

9. Lightingthe Appliance
Afterprolongedstorage,inspecttheBaseplateairholes(M1)forinsectssuchasspiders,whichcouldaffectgasflow.Ifthereisany
evidenceofinsects/nests,theBasePlatemustberemovedandanyforeignmaterialcleanedout. Afterchecking,re-fitallcomponents
intotheprescribedposition.
Usethisapplianceonlyonafirmlevelsurface.
Tolighttheappliance,lightamatchorbarbecuelighter.OpenuptheControlvalveslightly(O)asdescribedunder'General” andlightthe
applianceBurner(N).Whenstartingcold,theappliancemaybelitfromthetop(SeeFig.8b)priortofittingthedesiredcookingsurface
ontotheFatPan(B).Whenlightingupahotappliancehowever,itisrecommendedthatthisbedonebystickingthematchorbarbecue
lighterthroughoneofthelargerVentHoles(W)directlyunderneaththeBurner(N)(SeeFig.8c)
Precautionstoobservebeforelighting.
(Fig.2)pr
LightingupusingamatchorBBQlighter (SeeFig.8band8c)
General
TheControlvalveisclosedbyrotatingclockwiseuptoitsstoppositionandopenedbyanti-clockwiserotation.
AdjusttheflameintensitytothedesiredlevelbyturningtheControlknob(L)clockwisetodecreasetheflameandanti-clockwiseto
increaseit(SeeFig.8b&c).
TheflamemaybeobservedthroughtheInspectionHole(C) ovidedforthispurposeinthesideoftheFatPan(B).
Whencookingfoodwithahighfatcontent,flaringmayoccuriftheselectedheatsettingistoohigh.Shouldthishappen,turntheheat
downuntiltheflaringceases.
Donotmovetheappliancewheninuse,apartfrombeinganunsafepracticetomovetheappliancewhilstlititmaycauseflaring.
Afteruse,firstclosethevalveonthegascontainer(whereapplicable).Whentheflamehasextinguished,closethevalve(O)onthe
appliancebyturningtheControlKnob(L)fullyclockwise.