[*]-[9]-[3]  SET KEYPAD OPTIONS 
1.  Enter [*]-[9]-[3]  The LCD screen will prompt for a code. 
2.  Enter [program code] 
The LCD will now prompt you through the options 
listed in the following chart. The current state of the 
option will be shown in the lower right corner of the 
display. Press [*] to exit the current state without 
any changes. Otherwise, follow the directions on 
the bottom line to select the desired option. When 
finished, press [*] to move to the next option. 
OPT  KEYPAD FEATURES 
1 
CASE TAMPER ON? 
Tamper switch of keypad housing active 
2 
SILENT KEYPAD? 
Enable silent keypad option. If this is on, silent keypad is enabled for 
entry/exit delay and chime. 
3 
DING-DONG CHIME? 
Enable ding-dong sound for chime. If this is off, the chime will be a single 
tone. 
4 
5 SEC. SILENCE? 
Enable keypress silence option. Silences the pulsing keypad sounder for 5 
seconds when a key is pressed. 
5 
ARMED ZONE INFO? 
Enable armed status suppression. If this is on, the keypad will not display 
faulted or bypassed zones when the system is armed. 
6 
BEEP ON PANICS? 
Enable panic, fire, medical beep tone. Will sound a short beep to verify that 
the keypress has been accepted. 
7 
DISABLE SERVICE? 
Suppresses the “Service” Message. This will not allow the “Service” 
message to be displayed for any reason. If there is a system malfunction 
(trouble), pressing [*]-[2] will still display the “Service” menu. 
8 
MASTER KEYPAD? 
Enable multi-partition mode. 
9 
CUSTOM MESSAGE? 
Enable custom message display. 
10 
CLOCK? 
Enable clock display. 
11 
CUSTOM MSG. LOCK? 
Enable custom message lock. Prevents the custom message from being 
overwritten during keypad copy. 
12 
SELECT AN OPTION 
1234 - - - - 