Installation manual
GE Security 
g 
Reporting events to phone number 2 
Phone N°2 can be used to back up phone N°1, or as a second receiver to multi-report or 
split-report events. Phone N°2 has two programming locations that are used to select the 
events that are reported to this phone number. Location 10 is used to select the events 
which are reported to phone N°2, and location 11 is used to select which partitions are 
reported to phone N°2. If you do not want dual or split reporting, location 10 and location 
11 should be left at the factory default of “0”. If you want multi-reporting or split reporting, 
and the split is based on the event type (such as alarm, open close etc.), location 10 
should be used to select only those events that should be reported to phone N°2, and 
location 11 should be left at the factory default of “0”. If you want dual or split reporting, 
and the split is based on partition, then location 10 should be programmed as “0”, and 
location 11 should be used to select those partitions that are to be reported to phone N°2. 
If no events are to be reported to phone N°2, both locations should be at “0”. 
LOCATION 10 - EVENTS REPORTED TO PHONE N° 2 (2 segments of feature selection data) 
Segment 1 
1 =  Alarms 
  2 =  Opening and closings 
  3 =  Zone bypass and bypass restores 
  4 =  Zone trouble and trouble restores 
 5 = 
Power fail (AC failure), low battery, power restore (AC restore) , 
and low battery restore 
  6 =  Bell cut, bell cut restore, telephone line restore 
  7 =  Test reports 
  8 =  Start and end programming, download complete and log full 
Segment 2 
1 =  Zone and box tamper 
  2 =  Auxiliary power overcurrent, and restore 
  3 =  Wireless sensor missing and restore 
  4 =  Wireless sensor low battery and restore 
 5 = 
Expander trouble and restore (keypads are considered as 
expanders) 
  6 =  Fail to communicate 
  7 =  Alarm restore 
  8 =  Tamper restore 
LOCATION 11 - Reserved 
NX-4-EUR Installation manual  Page 36   08/09/04 