Zone configurations and partition selection 
DEFAULT ZONE CONFIGURATIONS 
Zones can be programmed to be one of thirty different zone configurations (zone types). 
The default zone configurations are listed below. Programming locations 110-169 can 
customise all zone configurations. 
DATA  R conf.  DESCRIPTION OF DEFAULT CONFIGURATION 
1 1 
DAY ZONE 
Instant when system is armed; trouble zone when system is disarmed. A day zone will 
only work if programmed for single end-of-line resistor. 
2 2 
24 HOUR AUDIBLE 
Creates an instant yelping siren alarm regardless of the arming state of the control 
panel. This zone type is not abortable. This zone can be bypassed. 
3 2 
ENTRY/EXIT DELAY 1 
A trip will start entry delay 1. Absence of a trip during the exit delay will enable the 
Automatic Bypass or Instant mode, if so programmed. 
4 2 
FOLLOWER (WITH AUTO- BYPASS DISABLED) 
This zone will be instant when the system is armed and no entry or exit delays are being 
timed. It is delayed during entry and exit delay times. This zone will not bypass 
automatically, even if enabled in segment 1 of location 23. 
5 2 
INTERIOR FOLLOWER (WITH AUTO- BYPASS ENABLED) 
This zone will be instant when the system is armed and no entry or exit delay is being 
timed. It is delayed during entry and exit delay times. This zone will bypass 
automatically, if enabled in segment 1 of location 23. 
6 2 
INSTANT 
This zone creates an instant alarm whenever it is tripped and the armed LED is on. 
7 2 
24 HOUR SILENT 
Creates an instant silent alarm regardless of the arming state of the control panel. It will 
not display on the keypad. This zone is not abortable, but can be bypassed. 
8 1 
FIRE 
This zone will light up the fire LED and sound the steady siren each time the zone is 
shorted. It will also rapidly flash the fire LED, indicating trouble if the zone is open. This 
zone cannot be bypassed. 
9 2 
ENTRY/EXIT DELAY 2 
A trip will start entry delay 2. Absence of a trip during the exit delay will enable the 
automatic bypass or instant mode, if so programmed. 
10 1 
24 HOUR AUDIBLE SUPERVISED 
Creates an instant audible alarm, regardless of the arming state of the control panel. It 
will display on the keypad (e.g. flashing zone LED’s, and changed READY LED). This 
zone is not abortable and cannot be bypassed. 
11 2 
MOMENTARY KEYSWITCH ZONE 
This zone type will arm and disarm the partition or partitions of the control panel where it 
is resident, every time the zone is shorted. Keyswitch arming will report as user 99. This 
zone type can only belong to 1 partition. 