Installation manual
GE Security 
g 
AUXILIARY OUTPUT EVENT SELECTION 
DATA  EVENT  DATA  EVENT 
09 Burglary alarm  289 Expander trouble 
19  Fire alarm  29  Dynamic battery test time 
29  24 hour alarm  30  Open period 
39  Trouble alarm  31  Closed period 
4 Tamper alarm  32 Listen-in 
5  Yelping siren  33  Line seizure 
6 Steady siren  34 Reserved 
7  Any siren  35  Fail to communicate 
8  Any bypass  36  Telephone line fault 
9  AC fail  37  Program mode 
10  Low battery  38  Download in process 
119 Duress  39  Reserved 
129  Aux 1 keypad (fire alarm)  40 
Short circuit (overcurrent on 12 
Vdc) 
139  Aux 2 keypad (medical alarm)  41  Box tamper 
149  Panic keypad  42  Siren tamper 
15 Keypad tamper   43 Any open 
169 Autotest  44  Any short 
17 Alarm memory  45 
Any fault (open/short on non-fire 
zone) 
18 Entry  469 Any alarm 
19 Exit  47 Beeping keypad 
20  Entry or exit 
48♦9 
Code entry (see note below) 
21 Armed state 
49♣9 
Key FOB function 1 
22 Disarmed state 
50♣9 
Key FOB function 2 
23 Ready  51 Always ON 
24  Not ready  52  Autoarm warning time 
25  Fire  53  Any siren when in away mode 
26 Fire trouble 
27 Chime 
54 
Progress of entry/exit (follows 
keypad buzzer) 
Note : 
♦ 
When event 48 is programmed, it is possible to program a user code authorisation 
to select the output(s), which a particular code will activate. When LED 8 is on for 
an authorisation, then LED’s -24 will correspond to the code that activates outputs 
1 - 2 respectively. (See “Programming the LED Keypads”) 
♣ 
Events 49 and 50 require one or more of the following to operate: wireless 
receivers or cardreaders. 
9 
If set to follow condition, these events will be 1 second. 
NX-4-EUR Installation manual  Page 51   08/09/04 