Installation manual
Glossary 
102  NX-8E Control Panel Installation Manual 
Automatic cancel/abort 
If enabled,  the cancel and/or abort features  are automatic 
(pressing  the Cancel button is not required). The  cancel and 
abort features  in Locations 23 and 40 must be enabled  to permit 
this auto feature  to work. For proper operation  of these features 
a dialer delay must be enabled.(Locations  40, 41, and 110 to 
169) 
Autotest 
This feature  causes the panel  to call the central station to report 
a communicator  test at a specified interval  (Location 51). 
Auxiliary outputs 
The  NX-8E  has four  programmable  outputs that are used to 
activate  relays, LEDs, etc. (Locations 45 to 50) 
Auxiliary power  overcurrent 
The  NX-8E  illuminates the Service  LED on the keypad 
whenever  too much current is drawn  from any device  powered 
by the system. This condition reports to the central station. 
(Location  37) 
Box tamper 
The  NX-8E  has an input for a normally  closed tamper switch. 
The  box tamper is programmed  to report and/or  sound the siren 
and/or  the keypad. (Locations 37 and 39). 
Built-in siren driver 
The  NX-8E  has a built-in 112 db siren driver  when  desired, this 
built-in driver  easily converts  to a 1A voltage output through 
programming  Location 37. 
Bypass toggle 
This feature  enables  the end user to toggle (turn off/on)  the 
bypass of an interior  zone with the system armed, by pressing 
the bypass key. (Location  23) 
Call back 
When enabled, the control panel  uses the call back phone 
number  to call the download  computer before  beginning a 
download. (Location 21). 
Cancel 
When enabled, the NX-8E sends a cancel report  when  the 
system is disarmed  and the Cancel button is pressed  within 5 
minutes of an alarm. Once the Cancel  button is pressed, the 
Cancel LED illuminates until the central station acknowledges 
the cancel report (a dialer delay must be enabled).  (Locations 
23 and 110 to 169) 
Code  required  options 
If programmed, the NX-8E  requires  a code for bypassing zones 
and/or  initiating a download  using the *, 9, 8 or *, 9, 9 functions. 
(Locations 23 and 41) 
Communication  formats 
The  NX-8E  reports in multiple formats. We recommend  that you 
use Contact ID or SIA formats if possible. if you want to report 
to a pager  or in a 4+2 format to a central station, you must 
program  each code to be reported.  (Locations 56 to 83) 
Cross zoning 
This feature  requires  two or more trips on a zone or zones 
programmed as cross zones within a specified time before 
reporting  an alarm. During  the time between  trips, the NX-8E 
sounds the keypad and/or the siren. The NX-8E  can also be 
programmed to report  an alarm after  two or more trips on the 
same zone. (Locations 37 and 40) 