Location 24 - Entry/exit times 
Location 24 has six segments of numerical  data. Use this location to program the 
entry/exit  times (there are two separate entry/exit  times). 
Segment 1 - Entry time 1. Entry time used when  a delay 1 zone type initiates an entry delay. 
Default  is 30, valid  entries 30 to 255 seconds. 
Segment 2 - Exit time 1. Exit time used for  all zones designated  as delay 1. Default  is 60, valid 
entries 45 to 255 seconds. 
Segment 3 - Entry time 2. Entry time used when  a delay 2 zone type initiates an entry delay. 
Default  is 30, valid  entries 30 to 255 seconds. 
Segment 4 - Exit time 2. Exit time used for  all zones designated  as delay 2. Default  is 60, valid 
entries 45 to 255 seconds. 
Segment 5 and 6 - Reserved 
Locations 25 to 36 - Zone type and partition selection 
Zones are programmed to be one of thirty  different types. To customize  a zone 
type, see Locations 110 to 169 (these are considered advanced programming 
and are only  to be changed with a thorough understanding  of the operation of 
each bit. 
Caution: We recommend the installer bench test any  custom zone types to 
ensure proper operation prior to making changes to a live system. 
Use zone types 17 through  20 for wireless, or for hardwired zones  using 
European double EOL configurations. 
Table 7: Zone types 
Zone type 
Description 
1. Day zone 
Instant when the system is armed; trouble  zone when  the system is 
disarmed. 
2. 24-hour  audible 
Creates an instant yelping siren alarm regardless  of the armed state 
of the control panel. 
3. Entry/exit delay 1 
A trip starts entry delay 1. The  lack of a trip during  exit delay enables 
the automatic bypass or instant mode if programmed. 
4. Follower  with auto 
bypass disabled 
Instant when the system is armed and no entry or exit delays are 
being timed. It is delayed 1 time during  entry and exit. It does not 
automatically bypass even  if enabled  in segment 1 of Location 23. 
5. Interior  follower  with 
auto bypass 
Instant when the system is armed and no entry or exit delay is being 
timed. It is delayed  1 time during  entry and exit. It automatically 
bypasses if enabled  in segment 1 of Location 23. 