Installation manual
  Chapter 2: Reporting codes 
NX-8E Control Panel Installation Manual  31 
Zone type 
Description 
21. Gas detection 
Creates an instant alarm regardless  of the armed  state of the control 
panel. It displays on the keypad and activates the keypad sounder. 
22. Low temperature 
detection 
Creates an instant silent alarm regardless  of the armed state of the 
control panel. It displays on the keypad and activates  the keypad 
sounder. 
23. High temperature 
detection 
Creates an instant silent alarm regardless  of the armed state of the 
control panel. It displays on the keypad and activates  the keypad 
sounder. 
24. Manual  fire 
Illuminates the Fire LED and sounds the temporal  siren each time the 
zone is shorted. it also flashes (rapidly)  the Fire LED, indicating a 
problem  if the zone is open. 
25. Chime  only 
This zone creates no alarm regardless  of the armed state of the 
control panel. It chimes anytime it is faulted  and displays on the 
keypad. Local only. 
26. Interior  follower  delay 
2 
Instant when the system is armed and no entry or exit delay is being 
timed. It is delayed  2 times during entry and exit. It automatically 
bypasses if enabled  in Segment 1 of Location 23. 
27. Interior  follower force 
armable 
Instant when the system is armed and no entry or exit delay is being 
timed. It is delay 1 time during  entry and exit. It automatically 
bypasses if enabled  in Segment 1 of Location 23. 
28. Entry/exit force 
armable  delay 2 
A trip starts entry delay 2. The  lack of a trip during  exit delay enables 
the automatic bypass or instant mode if programmed. 
29. Interior  follower  with 
activity supervision 
Instant when the system is armed and no entry or exit delay is being 
timed. It is delayed  during  entry and exit delay times. It sends a report 
if the zone activity time is reached  without a change of state (refer  to 
Segment 11 of Location  40). It automatically bypasses if enabled in 
Segment 1 of Location 23. 
30. Entry/exit with activity 
supervision 
A trip starts entry delay 1. It sends a report  if the zone activity time is 
reached  without a change of state (refer to Segment 11 of Location 
40). The lack of a trip during  exit delay enables the automatic bypass 
or instant mode if programmed. 
A zone may reside in any combination of the eight partitions. If a burglary  zone 
resides in more than one partition, it will only be active when  all partitions it 
resides in are armed. A zone that resides in more than  one partition will be 
reported to its lowest partition number. 