Location 37 - Siren and system supervision 
Location 37 has seven  segments of feature selection data. Use this location to 
enable various system feature and reporting options. 
Segment 1 
1. On if siren sounds for telephone line cut when armed. 
2. On if siren sounds for telephone line cut when disarmed. 
3. On if siren blast at arming. 
4. On if siren blast at exit expiration. 
5. On if siren blast at closing kissoff. 
6. On if siren sounds during  a cross zone verification  time. 
7. On if siren sounds for a zone or box tamper. 
8. On if siren blasts one time for keyswitch or wireless arming; two times for  disarming (must be 
disabled for  SIA CP-01).  Siren will blast four times when disarmed  if there is an alarm in 
memory. 
Segment 2 
1. On if siren driver should be a voltage  output; off  if on board  siren driver  is enabled. 
2. On if siren sounds for expander trouble. 
3. On for  immediate restore by zone; off  for zones to restore when  the siren times out. 
4. On if dynamic battery test performed  at arming; off  if performed  at disarming. 
5. On if battery missing test is done every  12 seconds, otherwise  panel tests at midnight. 
6. On if manual bell test is done during *-4-4  test function. 
7. On if manual communicator  test is done  during *-4-4  test function. 
8. On enables  box tamper terminals on the panel. 
Segment 3 
1. On enables  box tamper report. 
2. On enables  AC fail reporting. 
3. On enables  low battery reporting. 
4. On enables  auxiliary power  overcurrent  report. 
5. On enables  siren supervision  report. 
6. On enables  telephone  line cut report. 
7. On enables  ground  fault detection report. 
8. On enables  expander  trouble  report. 
Segment 4 
1. On enables  fail to communicate report. 
2. On enables  log full report. 
3. On enables  autotest report. 
4. On enables  start/end programming  report. 
5. On enables  end download  report. 
6. On enables  low battery report. 
7. On enables  sensor missing report. 
8. On enables  first to open/last to close report. 
Segment 5 
1. On enables  lost clock service  light 
2. On enables  zone doubling  (requires  NX-200  zone doubling  kit). 
3. On disables on board 8 zones. 