Installation manual
  Chapter 2: Reporting codes 
NX-8E Control Panel Installation Manual  35 
4. On allows two trips on same cross zone to activate  an alarm. 
5. On will not allow zones that are force  armed to report bypass. 
6. Reserved. 
7. On makes the clock use the internal  crystal. Only use if the panel is solely powered  by DC 
8. On disables the temporal  siren of fire. 
Segment 6 
1. On enables  two-wire  smoke. 
2. Reserved. 
3. On enables  zone activity in hours (not days). 
4. On enables  daylight saving  time (DST). 
5. On enables  DC only operation. 
6. On disables clean me report. 
7. On disables start/end walk test report. 
8. On enables  auto LED extinguish. 
Segment 7 - Reserved 
Location 38 - Swinger shutdown count 
Location 38 has one segment of numerical  data. Use this location to program the 
number of trips during an arming cycle that the NX-8E allows before bypassing a 
zone. The default is 1. 
Location 39 - Keypad sounder control 
Location 39 has one segment of feature selection data. 
Segment 1 
1. On if keypad sounds for a telephone line cut when the system  is armed. 
2. On if keypad sounds for a telephone line cut when the system  is disarmed. 
3. On if keypad sounds upon  AC power  failure. 
4. On if keypad sounds when  a low battery is detected. 
5. On if keypad sounds during  cross zone trip time. 
6. On if keypad sounds for zone and box tampers. 
7. Reserved. 
8. On if keypad sounds for expander  troubled. 
Location 40 - System timers 
Location 40 has 14 segments of numerical data. Use this location to program the 
duration of various system timing functions. 
Segment 1 -  Dynamic battery test duration  in minutes, 0 to 255 (0 = no test). Default  is 0. 
Segment 2 - AC fail report  delay in minutes, 0 to 255 (0 = no delay). Default  is 5. 