Installation manual
Chapter 2: Reporting codes 
42  NX-8E Control Panel Installation Manual 
Location 55 - Days of week each partition will automatically arm 
Location 55 has eight segments of feature selection data. Use this location to 
select which days each partition (1 to 8) will autoarm.  If a zone is faulted when 
the panel tries to autoarm, the zone bypasses. Default is 0 for each segment. 
For each segment (1 to 8), select the following: 
1 = Sunday 
2 = Monday 
3 = Tuesday 
4 = Wednesday 
5 = Thursday 
6 = Friday 
7 = Saturday 
8 = Disable 45 minute 
retry timer 
Locations 56 to 83 - 4+2 format communicator codes 
Use Locations 46 to 83 only  when reporting events to a pager or using a slow 
format such as 4+2. When  using Contact ID or SIA, you do not need to program 
these locations. There are eight segments of numerical data for each location 
and the default for all segments is 0. 
The digit programmed in each of the segments in these locations is sent as the 
upper hex  digit in place of the alarm event  code. The zone ID or user ID is 
reported as the lower hex digit (1-F). For example, if the zone  ID or user ID is 3, 
the 4+2 lower digit is 3. If the segment is left as 0 and the feature is enabled, the 
NX-8E reports A. 