Installation manual
Chapter 2: Reporting codes 
48  NX-8E Control Panel Installation Manual 
number.  If the account code is six digits long, program 
all six segments. 
Location 108 
Partition 8 feature  and reporting 
selection 
Location 108 has five  segments of feature  selection 
data. Use this location to enable  certain features  that 
are accessed or visible to the user from  the system 
keypad. In addition, certain communicator  reports are 
enabled  at this location. Each of these features  can be 
enabled  by partition (Location  23). 
Location 109 
Partition 8 entry and exit times 
Location 109 has six segments of numerical data. Use 
this location to program  the entry/exit times for partition 
8. There  are two separate entry/exit times (Location 
24). 
Locations 110 to 169 - Zone type characteristics 
Locations 110 to 169 are considered advanced programming and you should 
only  change them with a thorough  understanding  of the operation of each bit. 
Table 9 on page 49 lists the attributes for each location. 
Caution: We recommend the installer bench test any  custom zone types to 
ensure proper operation prior to making changes to a live system. 
Even-numbered locations 
Each even-numbered location has one segment of numerical data that programs 
the alarm event code for Contact ID or SIA. If 4+2 format is used, the number 
programmed in this location is sent as the upper hex digit. When using 4+2 
formats, the digits are from 1 to 15. The zone ID or user ID is the lower hex  digit 
of the zone  that is in alarm. 
Odd-numbered locations 
For odd-numbered  locations, the defaults represent the five segments of each of 
the locations separated by commas. 
Segment 1 
1. Fire. On if this is a fire zone. 
2. 24-hour.  On for nonfire  24-hour  zones. 
3. On for  keyswitch zone (normally open). 
4. Follower.  On for burglary  zones that are instant during nonentry  times). 
5. Delay 1 zone. One if zone follows  timer 1 entry and exit times. 
6. Delay 2 zone. On if zone follows timer 2 entry and exit times. 
7. Interior.  On if this zone automatically bypasses or bypasses for stay arming. 
8. Local only. On if this zone is not to be reported.. 