Installation manual
  Chapter 2: Reporting codes 
NX-8E Control Panel Installation Manual  49 
Segment 2 
1. On if zone type beeps the keypad for  alarm. 
2. On if zone type sounds the yelping siren for alarm. 
3. On if zone type sounds the temporal  siren for  alarm. 
4. On if zone type chimes. 
5. On if zone type is bypassable. 
6. On if zone type is included in the group  shunt. 
7. On if zone type is force armable. 
8. On if zone type is entry guard  (see Glossary) 
Segment 3 
1. On enables  fast loop response (50 mS; off = 500 mS). 
2. On enables  double  end of line tamper zone (mainly used to enable  the tamper on wireless 
zone.) 
3. On enables  trouble reporting  zone (day zones and fire zones). 
4. On if zone type is cross zoned. 
5. On enables  dialer delay zone (see Location 40). 
6. On if zone type is swinger shutdown  (see Location 38). 
7. On enables  restore reporting. 
8. On enables  listen in (see Location  40). 
Segment 4 
1. Enables zone activity monitor (see Location 40). 
2. On enables  end-of-line  resistor defeat  on zones that are not fire or keyswitch zones. 
3. On enables  zone to act as request to exit input/disables for  alarm activation. 
4. On enables  zone to act as access entry point. Do not enable  this segment unless configured 
with access control. 
5 to 8. Reserved. 
Segment 5 - Reserved 
Note: If dialer delay (Segment 3 Option 5) is turned  off, the panel  will not send cancel reports 
even if enabled  in Location 23. 
Table 9: Locations  110 to 169 
Location 
Zone 
type 
Description 
Default 
110 
1 
Alarm code 
8 
111 
1 
Feature  selection 
0, 125, 35678, 0, 0 
112 
2 
Alarm code 
2 
113 
2 
Feature  selection 
2, 125, 78, 0, 0 
114 
3 
Alarm code 
7 
115 
3 
Feature  selection 
5, 1245, 5678, 0, 0 
116 
4 
Alarm code 
5 
117 
4 
Feature  selection 
45, 125, 5678, 0, 0 
118 
5 
Alarm code 
5 
119 
5 
Feature  selection 
457, 125, 5678, 0, 0 