Installation manual
Chapter 2: Reporting codes 
52  NX-8E Control Panel Installation Manual 
Location 174 
Zones  65 to 72 zone 
types 
Location 174 has eight segments of numerical  data. Use this location 
to program  the zone type for zones  65 to 72. Use segment 1 for zone 
65, segment 2 for  zone 66, etc. The segment defaults  are 6, 6, 6, 6, 6, 
6, 6, 6. 
Location 175 
Zones  65 to 72 partition 
Location 175 has eight segments of feature  selection data. Use this 
location to select the partitions (1 to 8) that zones 65 to 72 reside in. 
Each segment corresponds  to a zone (segment 1 to zone  65, 
segment 2 to zone 66, etc.). In each segment, enter 1 for  partition 1 
through  8 for partition  8. 
Location 176 
Zones  73 to 80 zone 
types 
Location 176 has eight segments of numerical  data. Use this location 
to program  the zone type for zones  73 to 80. Use segment 1 for zone 
73, segment 2 for  zone 74, etc. The segment defaults  are 6, 6, 6, 6, 6, 
6, 6, 6. 
Location 177 
Zones  73 to 80 partition 
Location 177 has eight segments of feature  selection data. Use this 
location to select the partitions (1 to 8) that zones 73 to 80 reside in. 
Each segment corresponds  to a zone (segment 1 to zone  73, 
segment 2 to zone 74, etc.). In each segment, enter 1 for  partition 1 
through  8 for partition  8. 
Location 178 
Zones  81 to 88 zone 
types 
Location 178 has eight segments of numerical  data. Use this location 
to program  the zone type for zones  81 to 88. Use segment 1 for zone 
81, segment 2 for  zone 82, etc. The segment defaults  are 6, 6, 6, 6, 6, 
6, 6, 6. 
Location 179 
Zones  81 to 88 partition 
Location 179 has eight segments of feature  selection data. Use this 
location to select the partitions (1 to 8) that zones 81 to 88 reside in. 
Each segment corresponds  to a zone (segment 1 to zone  81 segment 
2 to zone 82, etc.). In each segment, enter 1 for  partition 1 through  8 
for partition 8. 
Location 180 
Zones  89 to 96 zone 
types 
Location 180 has eight segments of numerical  data. Use this location 
to program  the zone type for zones 89 to 96. Use segment 1 for zone 
89, segment 2 for  zone 90, etc. The segment defaults  are 6, 6, 6, 6, 6, 
6, 6, 6. 
Location 181 
Zones  89 to 96 partition 
Location 181 has eight segments of feature  selection data. Use this 
location to select the partitions (1 to 8) that zones 89 to 96 reside in. 
Each segment corresponds  to a zone (segment 1 to zone 89, 
segment 2 to zone 90, etc.). In each segment, enter 1 for  partition 1 
through  8 for partition  8. 
Location 182 
Zones  97 to 104 zone 
types 
Location 182 has eight segments of numerical  data. Use this location 
to program  the zone type for zones 97 to 104. Use segment 1 for zone 
97, segment 2 for  zone 98, etc. The segment defaults  are 6, 6, 6, 6, 6, 
6, 6, 6. 
Location 183 
Zones  97 to 104 partition 
Location 183 has eight segments of feature  selection data. Use this 
location to select the partitions (1 to 8) that zones 97 to 104 reside in. 
Each segment corresponds  to a zone (segment 1 to zone 97, 
segment 2 to zone 98, etc.). In each segment, enter 1 for  partition 1 
through  8 for partition  8. 