Installation manual
Appendix A: Reporting codes 
66  NX-8E Control Panel Installation Manual 
Reporting fixed codes in Contact ID and SIA 
The NX-8E can report SIA level 1 transmissions to either or both phone numbers. 
Each report consists of an event code and a zone ID (the zone number that is in 
alarm) or user ID. Table 13 below shows the event code programmed in the zone 
type event code. 
Table 13: Reporting fixed codes 
Contact ID event 
SIA 
Description 
301 
AT 
AC fail (device number) 
a
301 
AR 
AC restore (device  number) 
a
602 
RP 
Autotest 
b
312 
YP 
Aux power  overcurrent  (device  number) 
a
312 
YQ 
Aux power  restore (device number) 
a
137 
TA 
Box tamper (device  number) 
a
137 
TR 
Box tamper restore (device number) 
a
570 
U 
c
Bypass restore  (zone number) 
a
406 
OC 
Cancel (user number) 
a
401 
CL 
Close (user number) 
a
412 
RS 
Download  complete 
b
393 
YX 
CleanMe 
121 
HA 
Duress 
b
451 
OK 
Early open/late  close 
b
628 
LX 
End program 
b
605 
JL 
Event  log full 
b
457 
EE 
Exit error  (user number) 
a
333 
ER 
Expander  restore (device  number) 
a
333 
ET 
Expander  trouble (device  number) 
a
454 
CI 
Fail to close 
b
354 
RT 
Fail to communicate 
b
423 
DF 
Forced door 
b
423 
DR 
Forced door  restore 
b
310 
GF 
Ground  fault 
b
310 
GK 
Ground  fault restore 
b
110 
FA 
Keypad auxiliary 1 
b
100 
MA 
Keypad auxiliary 2 
b