15.1 DAILY OR WEEKLY CLEANING PERFORMED BY THE USER
15.2 BEFORE EACH START-UP
Clean the ash and any deposits in the brazier that could clog the air passage holes.
If the pellets in the hopper nish, unburned pellets may accumulate in the brazier. Always empty the residue in
the brazier before startingup.
REMEMBER THAT ONLY A CORRECTLY POSITIONED AND CLEAN BRAZIER CAN GUARANTEE
START-UP AND OPTIMAL OPERATION OF YOUR PELLET PRODUCT.
For the brazier to be cleaned properly, remove it from its housing completely and thoroughly clean all the holes
and the grate on the bottom.
If good quality pellets are used, you will normally only need to use a brush to restore the optimal operating
conditions of the component.
15.3 CLEANING THE GLASS
It is recommended to clean the ceramic glass with a dry brush, or if it is very dirty, spray a little specic detergent
and clean with a cloth.
ATTENTION!
Do not use abrasive products and do not spray the glass spray cleaner on the painted parts
or the door gaskets (ceramic bre cord).
15.4 CLEAN THE EXCHANGER AND THE UNDERGRATE SPACE EVERY 2/3 DAYS.
Cleaning the exchanger and the undergrate space is a simple operation but very important for always
maintaining performance as declared.
Therefore we recommend cleaning the internal exchanger every 2-3 days, performing these simple operations
in sequence:
Activate the “CLEANING” function – when the stove is switched of press - menu “3”, select“Settings”, with
the <> arrows “2-4” select “Cleaning”, conrm with “Menu” “3”, activate cleaning “ON” by pressing the +-
keys “5-6”. This procedure activates the smoke extraction fan on maximum power to expel the soot that is
dislodged when the exchanger is cleaned.
Clean the pipe unit – Using the hook provided, shake the rods located under the top (A to Fig. 39 page
46 and Fig. 40 page 46) vigorously 5-6 times. This operation removes the soot that has deposited on the
exchanger smoke ducts during normal stove operation.
Clean the smoke conveyor compartment see Fig. 39 page 46 for AQUOS 15-22-22 H2O / IBIS 15-22-22 H2O
/ IDRON 15-22-22 H2O models - Stoves are tted with a removable ash pan “C” designed to collect any soot
and ash build-up.
Clean the smoke conveyor compartment see Fig. 40 page 46 for IBIS 11 / IDRON 11 models - Open the
door, insert the hook onto the rod of the scraper B, shake it vigorously 5-6 times along the entire length.
Remove the hook and reposition the rod B fully in its seat. This will help the fan expel any soot build-up which
may have fallen during the previous pipe unit cleaning process. (After shaking the rods A, always shake the
scraper B too).
Disable the “CLEANING” function - this function is automatically disabled after two minutes. If one needs to
stop this function in advance press the “Esc” key.
If these cleaning operations are not performed every 2-3 days, the stove could go into
alarm conditions due to ash clogging after several hours of operation.