Operating Instructions and Installation Instructions
29
CLOE - CLOE
3
- SQUARE
EN
15
IN CASE OF ANOMALY
15.1 ALARMS
Before of every intervention of the Authorized Technician, the same Technician has the duty
to check that the parameters of the mother board correspond with those of the table you
own.
In case of doubts regarding the use of the stove, please call ALWAYS the Authorized
Technician in order to avoid irreparable damages!
ALARM CAUSE SOLUTION INTERVENTION
AL 1 - BLACK
OUT
Power cut during ignition
phase.
Clean the burning pot and switch the stove on again.
AL 2 - EXHAUST
PROBE
Disconnected fume
temperature probe
Have the stove checked.
Faulty fume temperature
probe
Replace the fume probe.
AL 3 - HOT
EXHAUST
Faulty fume probe Replace the fume probe.
Faulty mother board Replace the electronic board.
The exchanger fan does
not work
Replace the ambient fan.
Too high pellet drop
value
Adjust the pellet loading.
AL 4 - FAN
FAILURE
Faulty protection fuse of
the fume fan
Replace the fuse (1,25A).
Faulty fume fan
The pellets can burn also thanks to the chimney ue
depression and without the aid of the fume fan. Have
the fume fan replaced immediately. It can be noxious to
health to let the stove running without fume fan.