Operating Instructions and Installation Instructions
35
CLOE - CLOE
3
- SQUARE
EN
16.2 FEATURES
DESCRIPTION CLOE - CLOE
3
6,5 kW SQUARE 6,5 kW
WIDTH 82 cm 82 cm
DEPTH 28,5 cm 27 cm
HEIGHT with pedestal 91,5 cm 92 cm
WEIGHT with pedestal 92-98-107 kg 92-98 kg
INTRODUCED THERMIC POWER (Min/Max) 2,7 - 7,2 kW 2,7 - 7,2 kW
NOMINAL THERMIC POWER (Min/Max) 2,5 - 6,5 kW 2,5 - 6,5 kW
EFICIENCY (Min/Max) 93 - 89,5 % 93 - 89,5 %
FUME TEMPERATURE (Min/Max) 85 - 172 °C 85 - 172 °C
FUME MAXIMUM LOADING CAPACITY (Min/Max) 2,4 - 4,4 g/s 2,4 - 4,4 g/s
CO EMISSIONS (13% O
2
) (Min/Max) 0,050 - 0,008 % 0,050 - 0,008 %
OGC EMISSIONS (13% O
2
) 0,4 mg/Nm
3
0,4 mg/Nm
3
NO
X
EMISSIONS (13% O
2
) 110 mg/Nm
3
110 mg/Nm
3
Medium CO CONTENTS at 13% O
2
(Min/Max) 628 - 103 mg/Nm
3
628 - 103 mg/Nm
3
Medium POWDER CONTENTS at 13% O
2
(Max) 16 mg/Nm
3
16 mg/Nm
3
CHIMNEY DEPRESSION (Max) 11 Pa 11 Pa
MINIMUM SAFETY DISTANCE from ammable
materials
30 cm 30 cm
ON SHARED CHIMNEY FLUE NO NO
FUME OUTLET DIAMETER Ø80 mm Ø80 mm
COMBUSTIBLE Pellet Ø6-7 mm Pellet Ø6-7 mm
PELLETS HEATING VALUE 5 kWh/kg 5 kWh/kg
PELLETS HUMIDITY ≤ 10% ≤ 10%
HEATING VOLUME 18/20°C Coeff. 0,045 kW (Min/
Max)
60 - 156 m
3
60 - 156 m
3
HOURLY CONSUMPTION (Min/Max) 0,50 - 1,50 kg/h 0,50 - 1,50 kg/h
HOPPER CAPACITY 8 kg 8 kg
RANGE (Min/Max) 16 - 5,3 h 16 - 5,3 h
SUPPLY 230 V - 50 Hz 230 V - 50 Hz
POWER INPUT (Max) 350 W 350 W
INGNITER RESISTANCE POWER INPUT 300 W 300 W
MINIMUM EXTERNAL AIR INLET (last effective area) 80 cm
2
80 cm
2
STOVE WITH SEALED CHAMBER YES YES
EXTERNAL AIR INLET FOR SEALED CHAMBER Ø60 mm Ø60 mm