en PELLET STOVE installation, use and maintenance manual miriam - mary - pretty - verve - cristal ©2016 CADEL srl | All rights reserved – tutti i diritti riservati
EN Summary 1 MANUAL SIMBOLOGY.......................................... 3 2 DEAR CUSTOMER.................................................. 3 3 CAUTIONS............................................................. 3 4 SAFETY REQUIREMENTS......................................... 4 5 WARRANTY CONDITIONS..................................... 5 6 SPARE PARTS.......................................................... 6 7 WARNINGS FOR THE CORRECT DISPOSAL OF THE PRODUCT.............................................
1 EN MANUAL SIMBOLOGY • The icons with the stylized figures indicates whom the subject dealt in the paragraph is addressed to (between the User and/or the Authorized Technician and/or the Specialized Stove-repairer). • WARNING symbols indicates an important note.
EN 4 SAFETY REQUIREMENTS • Installation, electrical connection, functional verification and maintenance must only be performed by qualified or authorised personnel. • Live electrical parts: disconnect the product from the 230V power supply before performing any maintenance operation. Only power the product after completing assembly. • Special maintenance must only be performed by authorised and qualified personnel.
EN protecting gloves. • If the auger is blocked by a foreign object (for example: nails), and if it needs to be cleaned, do not remove the hand rejector and do not touch the auger. Please contact the Technical Assistance service. • The hand rejector can be removed exclusively by an authorized technician. • The chimney flue must be cleaned, since the soot and unburnt oil deposits reduce its section so blocking the draught. In great quantities they can flare up.
EN granted at part of any eventual and specific agreed conditions and in accordance with the fee in force for the work to be carried out. The user will also be charged for any costs incurred to remedy the incorrect technical interventions, tampering or damage to the appliance, not attributable to original faults. Save for the legal or regulatory limits, the guarantee does not cover the containment of atmospheric and acoustic pollution.
EN 9.2 CHIMNEY FLUE Fig. 1 - Chimney Flues LEGEND 1 2 3 4 5 Fig. 1 page 7 Chimney flue with insulated stainless-steel pipes Chimney flue on the existing chimney Inspection plug Inspection door ≥ 3,5 mt • The chimney flue or chimney is of great importance for the correct running of the heating appliance. • It is fundamental that the chimney flue is perfectly built and always maintained with a perfect efficiency. • The chimney flue must be sole (see Fig.
EN materials with thermal insulation and able to last against usual mechanical stresses. It must be insulated to avoid condensation and to reduce fume cooling effects. • The stove must be spaced out from fuels or flammable materials with an air gap or with insulating materials. Check the distance with the chimney manufacturer.
EN • The outlet height in the atmosphere must be away from the reflux area caused by the roof structure or by obstacles laying nearby (see Fig. 2 page 7). 9.7 CHIMNEY COMPONENTS Fig. 5 - Chimney components LEGEND 1 2 3 4 5 6 7 8 9 10 9.8 Fig. 5 page 9 Chimney pot Fume outlet Chimney flue Termal insulation External wall Chimney union Fume pipe Heat generator Inspection door T-union with inspection plug EXTERNAL AIR INLET Fig.
EN • It is mandatory to have an appropriate air intake connected to the outside to bring to the stove the air required for combustion. • The air inflow from outside to the inner occurs directly, through an opening on the external wall of the room (see Fig. 6 page 9). • Bedrooms, garages, and store of flammable materials are excluded.
EN 9.10 CHIMNEY FLUE CONNECTION Your pellet stove works through a fume draught forced by a fan. It is obligatory to check that all pipes are realized in compliance with the following regulation on material selection: EN 1856-1, EN 1856-2 e UNI/TS 11278. All must be effected by specialized personnel or companies as provided by UNI 10683:2012. • The connection between the appliance and the chimney flue should be short in order to favor the draught and to avoid condensation in the pipes.
EN 9.11 EXAMPLES OF CORRECT INSTALLATION Fig. 9 - Example 1 LEGEND 1 2 3 4 Fig. 9 page 12 Insulating material Reduction from Ø100 to Ø80 mm Inspection plug Minimum safety distance = 0,5 mt • Chimney flue installation Ø100/120 mm with an enlarged drilling for pipe transit. Fig. 10 - Example 2 LEGEND 1 2 3 4 5 6 Fig.
EN Fig. 11 - Example 3 LEGEND 1 2 3 Fig. 11 page 13 Insulating material Inspection plug Minimum safety distance = 0,5 mt • External chimney flue entirely made up of insulated stainless steel pipes, i.e. with double wall of minimum Ø100/120 mm: all must be firmly attached to the wall. For chimney against wind effects please (see Fig. 4 page 8). • Ducting system through T-unions which enables an easy cleaning without disassembling the pipes.
EN 11 INSTALLATION 11.1 INTRODUCTION • The assembly position must be chosen depending on environment, outlet, chimney flue. • Check with local authorities if there are any restrictive regulations which regard the combustible air inlet, room ventilation, fume exhaust system together with chimney flue and chimney pot. • Check if there is the combustible air inlet. • Check the probable presence of other stoves or appliances which could depress the room.
EN LEGEND 8 Fig. 12 page 14 Hole combustion air inlet d.4 cm Fig. 13 - General dimensions: Mary LEGEND 1 2 3 4 5 6 7 8 MIRIAM - MARY - PRETTY - VERVE - CRISTAL Fig. 13 page 15 51,8 cm 99,5 cm 46,5 cm 26,5 cm 17 cm 11 cm Exhaust fumes d.8 cm Hole combustion air inlet d.
EN Fig. 14 - General dimensions: Pretty LEGEND 1 2 3 4 5 6 7 8 16 Fig. 14 page 16 51,5 cm 94,5 cm 46,5 cm 26,5 cm 17 cm 11 cm Exhaust fumes d.8 cm Hole combustion air inlet d.
EN Fig. 15 - General dimensions: Verve LEGEND 1 2 3 4 5 6 7 8 MIRIAM - MARY - PRETTY - VERVE - CRISTAL Fig. 15 page 17 48,5 cm 95,5 cm 48,5 cm 26,5 cm 17 cm 11 cm Exhaust fumes d.8 cm Hole combustion air inlet d.
EN Fig. 16 - General dimensions: Cristal LEGEND 1 2 3 4 5 6 7 8 11.3 Fig. 16 page 18 51,5 cm 94,5 cm 46,5 cm 16,7 cm 17 cm 11,2 cm Exhaust fumes d.8 cm Hole combustion air inlet d.4 cm GENERAL INSTALLATION Fig. 17 - General installation LEGEND 1 2 18 Fig.
EN LEGEND 3 4 Fig. 17 page 18 Minimum rear distance = 200 mm Minimum front distance = 1000 mm • It is obligatory to install the stove away from walls and/or pieces of furniture, with a minimum air flow of 300 mm on the sides and 200 mm on the back, to enable an eficient appliance cooling and a good distribution of heat in the room (see Fig. 17 page 18). • If the walls are made up of flammable materials, check the safety distances (see Fig. 17 page 18).
EN • The narrow side panel is to clasp on the squared holes (see Fig. 22 page 19). • Recompose all. 11.5 MOUNTING THE SIDE PANELS (VERVE) Fig. 23 - Removing the upper screws Fig. 24 - Removing the lower screws • The screws to fasten the sides are already positioned on the stove, remove them (see and ). Fig. 25 - Screw removal Fig. 26 - Removing the lower panel Fig. 27 - Removing the upper panel • Keeping the door closed, remove the screws from the lower panel (see Fig.
EN Fig. 30 - Hook-on the panel Fig. 31 - Panel upper fixing Fig. 32 - Panel lower fixing • Hook the teeth of the panel onto the provided slots on the side of the stove (see Fig. 30 page 21). • Fix the panel on the front part of the stove with screws (see Fig. 31 page 21 and Fig. 32 page 21). METAL SIDE: Fig. 33 - Hook-on the panel Fig. 34 - Panel upper fixing Fig.
EN Fig. 36 - Electric socket with master switch • The master switch O/I (see Fig. 36 page 22) is to open only to switch the stove on, otherwise it is advisable to keep it off. • Do not use extension cables. • If the feeder cable is damaged, it must be replaced by an authorized technician. • When the stove is not going to be used for a long period of time, it advisable to remove the plug from the socket on the wall. 11.
EN Oily plant waste and lacquers can cause smells and smoke during the first working hours: it is advisable to ventilate the room because they could be noxious to people and animals. Set values from 1 to 5 are defined by the manufacturer and they can be changed only by an authorized technician. 12.2 CONTROL PANEL PANEL ELEMENT DESCRIPTION P1 and P2: when in set temperature mode, they are useful to increase or decrease the thermostat value from min. 6°C to max 40°C.
EN Fig. 38 - LCD control display LEGEND 1 2 3 4 5 12.3 Fig. 38 page 24 Time Power State Message Temperature USER MENU By once pressing P3 key you can hace access to user parameter controlling. To let them slide press P5 and P6 keys. They are: POS. REFERENCE DESCRIPTION 1 SET CLOCK Set date and time. The board is provided with a lithium battery which enables a clock autonomy of 3/5 years. See CLOCK SETTING page 26. 2 SET CHRONO Press once P3: "CHRONO ENABLE" appears.
EN 12.5 STOVE ADJUSTMENT The stove is adjusted according to the chimney flue and used pellets datas, as per technical characteristics (see FEATURES page 39). If the datas do not correspond, the authorized technician can adjust the stove.
EN 12.10 FUME TEMPERATURE To check the fume temperature at the exhaust it is sufficient to keep pressed P2 key. 12.11 SWITCHING OFF To switch the stove off, keep pressed P4 key: the display shows "FINAL CLEANING". After about 10 minutes, also the fume fan switches off (this happens always, independently if the stove is hot or cold). Then "OFF" will be shown. 12.12 CLOCK SETTING • Press P3 key and then P5 key till underlining "SET CLOCK" menu (02).
EN 12.16 PELLET SUPPLY Fig. 40 - Wrong opening of the pellets bag Fig. 41 - Right opening of the pellets bag It is necessary to avoid to fill the hopper with the pellet when the stove is running. • Do not get the bag of pellet in contact with hot stove surfaces. • Do not empty the hopper with remaining fuels (unburnt pellet) from the burning pot coming from ignition waster. 12.17 REMOTE CONTROL • The stove can be operated through a remote control. • Operation requires 1 CR 2025 Lithium battery.
EN 13 SAFETY SYSTEM 13.1 INTRODUCTION Safety devices are used to prevent and avoid the risk of damages to people, animales and objects. It is forbidden to execute repearing by no authorized personnel otherwise the warranty and the manufacturer liability fall. 13.2 "BLACK OUT" ALARM "ACTIVE ALARM" "AL 1 - BLACK OUT": current breaking during ignition. • Reset the error with P4 key.
EN power supply to the auger. • Reset the error with P4 key. The stove carries out the phase "FINAL CLEANING" and then is in "OFF". • Check the type of glitch as ALARMS page 33. • Unscrew the black cap, press the button and screw the cap again. • Clean the burning pot and start the stove up again with P4 key. 14 MAINTEINANCE 14.1 INTRODUCTION For a long working life of the stove, have a periodic cleaning of the stove as described in the following paragrafs.
EN • The ash remains have to be stored in a metal container with a sealed lid and this container must never get in touch with combustible materials (for example put on a wooden floor), as the inner ash keeps the embers firing for a long time. • Only when the embers are off the ash coul be poured in the organic waste. • Pay attention if the flame becomes red colured, if it is weak or if black smoke creates in the inner: in this case the burning pot is encrusted and needs to be cleaned.
EN Fig. 51 - Fume conduit cleaning • Remove the inspection lid of the T-union (see Fig. 51 page 31). • Extract the ash which has accumulated in the inner. • After the cleaning repeate the opposite operation checking the integrity and eficiency of the gasket: if necessary have it replaced by an Autorized Technician. It is important to sealed the cap othrwise noxiuous fumes will propagate among the room. 14.
EN Fig. 57 - Fume passages cleaning • • • • Fig. 58 - Silicon laying Fig. 59 - Fume passages Clean the fume passages with the aid of a brush (see Fig. 57 page 32). Lay the silicon round the hole (see Fig. 58 page 32) and screw again the lids. Reassemble all. Clean the 2 pipes inside the combustion chamber (placed on the top) with a pipe cleaner (see Fig. 59 page 32). 14.8 FUME PIPES ANNUAL CLEANING Clean once a week from soot with brushes.
EN You should clean the fire door glass every day! 15 IN CASE OF ANOMALY 15.1 ALARMS Before of every intervention of the Authorized Technician, the same Technician has the duty to check that the parameters of the mother board correspond with those of the table you own. In case of doubts regarding the use of the stove, please call ALWAYS the Authorized Technician in order to avoid irreparable damages! ALARM CAUSE SOLUTION AL 1 - BLACK OUT Power cut during ignition phase.
EN ALARM CAUSE SOLUTION INTERVENTION Empty hopper Fill the hopper. The burning pot has not been cleaned Clean the burning pot. The ignition threshold has not been reached Clean the burning pot and switch the stove on again. Faulty ignition plug Replace the ignitor resistance. Too sever external temperature Start the stove up again. Humid pellet The pellets must be stored in a dry place. Please check it. Blocked thermal probe Replace the thermal probe.
EN ALARM AL 8 - FAILURE DEPRESS 15.2 CAUSE SOLUTION Obstructed exhaust The exhaust chimney is partially or totally obstructed. Call en expert stove-repairer who executes a check from the exhaust up to the chimney pot. Fume fan out of order The pellet can burn also thanks to the chimney flue depression without the aid of the fan. Have the fume fan immediately replaced. It can be noxious to health to let the stove running without fan. Obstructed connecting nozzle Clean the connecting nozzle.
EN PROBLEM CAUSE SOLUTION The stove is without power supply Check if the plug is connected. Burned protection fuse in the electric socket Replace the protection fuses in the electric socket (3.15A-250V). The control display Faulty control does not switch display on Pellets do not reach the combustion chamber INTERVENTION Replace the control display. Faulty flat cable Replace the flat cable. Faulty electronic board Replace the mother board. Empty hopper Full the hopper.
EN PROBLEM Flames are weak and orange coloured, pellets do not burn properly and the glass blackens The exchanger fan continues to turn even though the stove has just cooled CAUSE SOLUTION Not sufficient combustion air Check as following: probable obstructions of the combustible air inlet from the back or from the bottom of the stove; burning pot obstructed holes with too ash remains. Have the fan blades and auger cleaned. Obstructed exhaust The exhaust chimney is partially or totally obsturcted.
EN 16 TECHNICAL DATAS 16.1 REPAIR INFORMATION Now we give some instructions for the Authorized Technician to take into consideration to have access to stove mechanical components. • For fuse replacement in the electric socket which stands on the back of the stove, extract the fuses to change with the aid of a screwdriver for opening the shutter (see Fig. 60 page 38). Fig. 60 - Shutter with fuses to remove Proceed as follows: • Release the cap.