Operating Instructions and Installation Instructions

18
VEGA - SIRE
3
PLUS - DOGE
3
PLUS - SFERA
3
- SFERA
3
PLUS - PRINCE
3
- PRINCE
3
PLUS - GLOBE - TREND - ELISE
3
PLUS
EN
LEGEND Fig. 19 page 17
1 65 cm
2 108 cm
3 60,3 cm
4 45°
5 5,5 cm
6 30,3 cm
7 22,7 cm
8 11,7 cm
9 8,2 cm
10 22 cm
11 Exhaust fumes d.8 cm
12 Hole combustion air inlet d.6 cm
13 Ducting outlet
11.3 GENERAL INSTALLATION
Fig. 20 - General installation
LEGEND Fig. 20 page 18
1 Stove
2 Minimum lateral distance = 300 mm
3 Minimum rear distance = 200 mm
4 Minimum front distance = 1000 mm
It is obligatory to install the stove away from walls and/or pieces of furniture, with a minimum air ow of 300 mm
on the sides and 200 mm on the back, to enable an ecient appliance cooling and a good distribution of heat
in the room (see Fig. 20 page 18).
If the walls are made up of ammable materials, check the safety distances (see Fig. 20 page 18).
At maximum power check that the wall temperature does not ever exceed 80°C. If it would be necessary please
install a re resistant plate on the concerned walls.
In some countries also masonring load-bearing walls are considered ammable.
11.4
FRONTAL PANEL ASSEMBLY (VEGA / TREND / PRINCE
3
/ PRINCE
3
PLUS MODELS)
For frontal panel installation, proceed as follows: