Operating Instructions and Installation Instructions
23
VEGA - SIRE
3
PLUS - DOGE
3
PLUS - SFERA
3
- SFERA
3
PLUS - PRINCE
3
- PRINCE
3
PLUS - GLOBE - TREND - ELISE
3
PLUS
EN
Fig. 44 - Upper pipe position Fig. 45 - Upper hot air outlet
Fig. 46 - Back pipe position Fig. 47 - Back hot air outlet
• The hot air can be forced in ducts in the upper part (see Fig. 44 page 23 and Fig. 45 page 23).
• Or make the air exit from the rear (see Fig. 46 page 23 and Fig. 47 page 23).
Fig. 48 - Ducting system example
• If the stove is not tted with ducting system, it provide a hot air capacity ranging from a minimum of 61 m
3
/h
to a maximum of 130 m
3
/h with a temperature ranging between 90°C and 136°C.
• For the ducting system, we recommend using a pipe with a maximum length of 6 mt and up to three 90°
elbows in order to maintain hot air temperature.
• Use pipes with smooth internal surface and a diameter of 80 mm.