Operating Instructions and Installation Instructions

23
VEGA - SIRE
3
PLUS - DOGE
3
PLUS - SFERA
3
- SFERA
3
PLUS - PRINCE
3
- PRINCE
3
PLUS - GLOBE - TREND - ELISE
3
PLUS
EN
Fig. 44 - Upper pipe position Fig. 45 - Upper hot air outlet
Fig. 46 - Back pipe position Fig. 47 - Back hot air outlet
The hot air can be forced in ducts in the upper part (see Fig. 44 page 23 and Fig. 45 page 23).
Or make the air exit from the rear (see Fig. 46 page 23 and Fig. 47 page 23).
Fig. 48 - Ducting system example
If the stove is not tted with ducting system, it provide a hot air capacity ranging from a minimum of 61 m
3
/h
to a maximum of 130 m
3
/h with a temperature ranging between 90°C and 136°C.
For the ducting system, we recommend using a pipe with a maximum length of 6 mt and up to three 90°
elbows in order to maintain hot air temperature.
Use pipes with smooth internal surface and a diameter of 80 mm.