Operating Instructions and Installation Instructions
34
VEGA - SIRE
3
PLUS - DOGE
3
PLUS - SFERA
3
- SFERA
3
PLUS - PRINCE
3
- PRINCE
3
PLUS - GLOBE - TREND - ELISE
3
PLUS
EN
Fig. 72 - Loosen the top screw Fig. 73 - Loosen the bottom screw Fig. 74 - Remove side panels
• Clean the 2 pipes inside the combustion chamber (placed on the top) with a pipe cleaner (see Fig. 75 page
34, Fig. 77 page 34 and Fig. 76 page 34).
• Loosen the two screws from the galvanised panel closing the ue gas compartment, which is found on both
sides of the stove (see Fig. 78 page 34).
• Clean with a pipe cleaner and suction any ash accumulated inside (see Fig. 79 page 34 and Fig. 80 page 34).
• After the cleaning the opposite operation is to repeat checking the gasket efciency and integrity: if necessary
provide for its replacement by an Authorized Technician.
Fig. 75 - Fume passages Fig. 76 - Cleaning with a brush 1 Fig. 77 - Clean both the ducts
Fig. 78 - Fume chamber Fig. 79 - Cleaning with a brush 2 Fig. 80 - Fume chamber cleaning
14.5 FUME CONDUIT CLEANING
The exhaust system must be cleaned every season (or every 1500 operation hours).