Operating Instructions and Installation Instructions
Table Of Contents
- 1 INTRODUCTION
- 2 MISES EN GARDE
- 3 MISES EN GARDE POUR L’ÉLIMINATION CORRECTE DU PRODUIT
- 4 CONDITIONS DE GARANTIE
- 5 INSTRUCTIONS POUR L’INSTALLATION
- 6 DESSINS ET CARACTERISTIQUES TECHNIQUES
- 7 INSTALLATION ET MONTAGE
- 8 RACCORDEMENT HYDRAULIQUE
- 8.1 RACCORDEMENT DISPOSITIF HYDRAULIQUE
- 8.2 SCHEMA DE BRANCHEMENT POELE (AQUOS 15 - 22 / IBIS 15 - 22 / IDRON 15 -22)
- 8.3 SCHEMA RACCORDEMENT POELE HYDRO EQUIPEE DU KIT DE PRODUCTION D’EAU SANITAIRE (AQUOS 22 H2O / IBIS 22 H2O / IDRON 22 H2O)
- 8.4 SCHEMA DE RACCORDEMENT POELE HYDRO (IBIS 11 / IDRON 11)
- 8.5 RACCORDEMENT DU DISPOSITIF
- 8.6 REMPLISSAGE DU DISPOSITIF
- 8.7 KIT PRODUCTION EAU SANITAIRE (uniquement poêles AQUOS 22 H2O / IBIS 22 H2O / IDRON 22 H2O)
- 8.8 CARACTERISTIQUES DE L’EAU
- 9 RACCORDEMENTS ELECTRIQUES
- 10 PREMIER ALLUMAGE
- 11 RUBRIQUES DU MENU
- 12 NOTIONS PRELIMINAIRES
- 13 FONCTIONNEMENT
- 13.1 MODES DE FONCTIONNEMENT
- 13.2 RACCORDEMENT THERMOSTAT EXTERIEUR (e)
- 13.3 ALLUMAGE
- 13.4 EROGATION DE PUISSANCE
- 13.5 MODE PROGRAMME (TIMER) - Menu principal
- 13.6 EXEMPLES DE PROGRAMMATION
- 13.7 REMARQUES POUR LE FONCTIONNEMENT TIMER
- 13.8 MODE AUTO ECO (voir points f-g MENU CONFIGURATIONS a pag. 29)
- 13.9 FONCTION SLEEP (menu principal)
- 13.10 CHAUDIERE AUXILIAIRE (voir point i MENU CONFIGURATIONS a pag. 29)
- 13.11 RECETTE PELLETS (voir point j MENU CONFIGURATIONS a pag. 29)
- 13.12 VARIATION RPM FUMEES (voir point k MENU CONFIGURATIONS a pag. 29)
- 13.13 T ON POMPE (uniquement pour usagers experts) - voir point h MENU CONFIGURATIONS a pag. 29
- 13.14 PUISSANCE MAXIMALE (uniquement pour usagers experts) - voir point l MENU CONFIGURATIONS a pag. 29
- 13.15 FONCTION RAMONAGE (uniquement pour les agents de maintien) - voir point n MENU CONFIGURATIONS a pag. 29
- 13.16 FONCTION SAISON (voir point p MENU CONFIGURATIONS a pag. 29)
- 13.17 CHARGEMENT VIS SANS FIN (voir point d MENU CONFIGURATIONS a pag. 29)
- 13.18 TEST COMPOSANTS (voir point m MENU CONFIGURATIONS a pag. 29)
- 14 DISPOSITIFS DE SECURITE ET ALARMES
- 14.1 LES DISPOSITIFS DE SECURITE
- 14.2 PRESSOSTAT
- 14.3 SONDE TEMPERATURE FUMEES
- 14.4 THERMOSTAT A CONTACT DANS LE RESERVOIR COMBUSTIBLE
- 14.5 THERMOSTAT A CONTACT DANS LA CHAUDIERE
- 14.6 SONDE TEMPERATURE EAU
- 14.7 DISPOSITIFS DE SECURITE ELECTRIQUE
- 14.8 VENTILATEUR FUMEES
- 14.9 MOTOREDUCTEUR
- 14.10 DEFAUT TEMPORAIRE DE COURANT
- 14.11 DEFAUT D’ALLUMAGE
- 14.12 FONCTION ANTIGEL
- 14.13 FONCTION ANTIBLOCAGE POMPE
- 14.14 SIGNALISATIONS DES ALARMES
- 14.15 MISE A ZERO DE L’ALARME
- 14.16 ARRET NORMAL (sur le panneau : OFF avec flamme clignotante)
- 14.17 COUPURE DE COURANT AVEC POELE ALLUME
- 14.18 BLACKOUT SUPERIEUR A 10” AVEC POELE EN PHASE D’ARRET
- 15 NETTOYAGE ET MAINTENANCE
- 15.1 NETTOYAGE QUOTIDIEN OU HEBDOMADAIRE PAR L’UTILISATEUR
- 15.2 AVANT CHAQUE ALLUMAGE
- 15.3 NETTOYAGE DU VERRE
- 15.4 NETTOYAGE DE L’ECHANGEUR ET DU COMPARTIMENT SOUS-BRASIER TOUS LES 2/3 JOURS
- 15.5 NETTOYAGES PERIODIQUES PAR LE TECHNICIEN SPECIALISE
- 15.6 NETTOYAGE DE L’ECHANGEUR DE CHALEUR
- 15.7 NETTOYAGE ECHANGEUR ET FAISCEAU TUBULAIRE (AQUOS 15-22-22 H2O / IBIS 15-22-22 H2O / IDRON 15-22-22 H2O)
- 15.8 NETTOYAGE COMPARTIMENT SUPERIEUR
- 15.9 NETTOYAGE COMPARTIMENT INFERIEUR
- 15.10 NETTOYAGE ECHANGEUR ET FAISCEAU TUBULAIRE (IBIS 11 / IDRON 11)
- 15.11 NETTOYAGE COMPARTIMENT SUPERIEUR
- 15.12 NETTOYAGE COMPARTIMENT INFERIEUR
- 15.13 NETTOYAGE TUYAU DE FUMEE ET CONTROLES EN GENERAL :
- 15.14 MISE EN HORS SERVICE (fin de saison)
- 16 PANNES/CAUSES/SOLUTIONS
34
AQUOS - IBIS - IDRON
FR
12
NOTIONS PRELIMINAIRES
12.1 CONFIGURATIONS DU DISPOSITIF EN FONCTION DU MODELE
Au moment de l’installation, le produit doit être conguré en fonction de type du dispositif en sélectionnant le
paramètre
”CONFIGURATIONS” prévu à cet effet dans le menu.
Les congurations possibles sont au nombre de 5, comme décrit ci-dessous :
CONFIGURATION DESCRIPTION
1
Gestion température ambiante au moyen de la sonde à bord du poêle ou en activant le
thermostat d’ambiance extérieur.
2
2.1 Gestion température ambiante au moyen de la sonde à bord du poêle ou en activant
le thermostat d’ambiance extérieur; production d’ACS instantanée avec l’échangeur à
plaques.
2.2 Gestion température d’ambiance au moyen de la sonde à bord du poêle ou en
activant le thermostat d’ambiance extérieur; production d’ACS pour chauffe-eau ou ballon
d’accumulation avec thermostat (en option).
3
Gestion température ambiante au moyen de la sonde à bord du poêle ou en activant le
thermostat d’ambiance extérieur; production d’ACS chauffe-eau avec sonde ntc (10 kΩ ß3435).
4 Gestion puffer extérieur commandé par le thermostat.
5 Gestion puffer extérieur commandé par sonde ntc (10 kΩ ß3435).
Fig. 26 - Conguration 1 (reglade en usine version chauffage seul)